P/N 033000=13610 Rev. 01-02-06 BMB Home Security
13
4.1.2 Using the Door/Window Sensor
1. Open the casing by taking the two parts apart..
2. Insert batteries (2xAAA, alkaline) into the battery compartment. Observe polarity.
3. Set the switch for entry delay (5) to MIN when you have installed the sensor on a window and on MAX when
the sensor is installed on a door. When the switch is set to MAX, you have time to open and close the door
without triggering the alarm. If you want an instant alarm (on e.g. the backdoor), set the switch to MIN.
4. Activate the sensor by pressing the tamper contact (6) on the transmitter for 4 seconds. Release the button.
The door/window sensor has now chosen a unique code, which can be registered with your console.
4.1.3 Registering a Door/Window Sensor with the Console
1. To access the menu, press either the menu UP ?
or DOWN ?
button. The display now shows
ENTER PIN.
2. Enter your 4-digit PIN code (factory setting 0000. See 8.3 for changing the PIN code). The display is cleared
and shows a * for each number entered.
3. When the PIN code has been entered correctly, the word
INSTALL
will show up on the display.
4. Press OK.
5. Open your door or window. The console will beep to confirm. The display will read
ZONE 1 SET.
A memory space for a sensor is called a zone. If you have more than 1 sensor installed, it will show e.g.
ZONE 2
SET, ZONE 3 SET, … ZONE 30 SET
.
You can choose in which zone you want to install the sensor. If you want to install the sensor in zone 3, press 3
on the number pad before executing step 5.
It’s advisable to write down which zone contains which sensor. There’s space reserved at the back of this user
manual.
6. Repeat step 5 for every door/window sensor you wish to register.
7. Press CLEAR to go back to the first menu item. Press CLEAR again to quit the menu. To confirm this choice,
press 1 for Yes or 2 for No. If you choose Yes, you will quit the menu. If you choose No, you go back to the first
menu item.
4.1.4 Adding a wired sensor to the D/W sensor
The DS18 Door/Window Sensor has a contact for an
extra wired sensor. These sensors need to be of type NC
(normally closed dry contacts) and there should not be
any power on this contact (potential-free).
1. Open the transmitter part of the DS18.
2. Remove the wire bridge from the connection for the
wired sensor (6).
3. Connect your additional sensor.
The wired contact can have its dedicated zone
registration on the Security Base Console. You can
register the contact using the procedure as described
above.
To register the sensor, trigger the alarm of your wired
sensor while in registry mode.