Installation
12
[ I ]
Installation
DANGER
Please regard the safety advices in part General [G]. Observe all notes with respect to safety
and use of the freeAir plus.
Notes
• Your freeAir plus draws stale air from the room that is connected via the freeAir plus. To
ensure an unhindered air inflow from the Outdoor Air Room (e.g. carridor) to the
Preferred Room, please take care that there is an
appropriate opening with a cross section
of at least 80 cm
2
(e.g. a gap under the door of 1 cm).
• The side of the device with the operating element is mounted in the Outer Room
• The Outdoor Air Room is continuously supplied with fresh air by a freeAir 100 ventilation
unit.
Installation site
DANGER
• The freeAir plus must not be installed in immediate vicinity of flammable material or
harmful chemicals.
• During planning consider all relevant local building, safety and fire codes. Especially in
situations where indoor air is used for combustion (wood stove, fire place...etc.).
Notes
• During operation the room temperature must be between 0°C and 40°C.
• Condensation of water must not occur in the freeAir plus unit.