background image

  

 

Service 

 

 

 

 

[ S ]  25 

 

Commissioning

 

Date: 

 

 

 

Serial number: 

 

Company:  

 

 

 

Name: 

 

 

 

 

Signature: 

 

Summary of Contents for freeair plus

Page 1: ...Operating Manual G General O Operation I Installation S Service ...

Page 2: ...n Turbo Reset If you want to ventilate your rooms on the highest fan level for 30 minutes Turbo mode push the Button until you hear 4 short beeps The unit performs a software reset when you press the Button for 15 more seconds until the LEDs turn off This is e g required for software updates Standby The unit switches on as soon as it is connected to the power supply When the unit is not needed you...

Page 3: ...e read and follow this manual thoroughly After successful installation please select the desired Comfort Level The sensor technology and the intelligent control of your freeAir will do the rest Enjoy the heightened sense of wellbeing offered by constant good air quality Your bluMartin Team ...

Page 4: ...s manual Installation commissioning and servicing must only be performed by sufficiently qualified personnel Failure to comply with this manual voids the warranty Please also observe our general terms and conditions at www bluMartin de cos Safety Icons DANGER This sign indicates danger by potentially deadly electrical shock DANGER This sign indicates that instructions must be followed precisely in...

Page 5: ...nstallation has to be in accordance with the appropriate national association or the safety regulations of your country All instructions and notes with respect to maintenance see Service paragraph are to be implicitly followed The device may only be operated in perfect technical condition and unaltered condition In case of error or damages that constitute a safety issue turn the device off Prevent...

Page 6: ...h another appropriate passive vent If the measured air quality in the Outdoor Air Room is lower than in the Preferred Room the ventilation is reduced Inappropriate use The device is exclusively to be used for ventilation purposes DANGER Only air not containing flammable explosive or corrosive components or air not containing any other dangerous or hazardous components may be used for ventilating p...

Page 7: ...eneral 5 G Transport and storage Components of the freeAir plus may only be transported in the intended packaging Packaging must be protected from moisture Included in shipping freeAir plus front plates ...

Page 8: ...l Power Consumption Standby 0 5 W 30 m3 h 0 9 W 50 m3 h 1 4 W 70 m3 h 2 5 W Weight 3 kg Sound pressure level 30 m3 h 13 dB A at 1 m distance 50 m3 h 25 dB A 70 m3 h 37 dB A Sound insulation factor 33 dB EN ISO 10140 2 Dn e w Control Intelligent 5 level Comfort Control Airflow control Automatic virtually infinitely variable CO2 control VOC Automatic Dehumidification Automatic Summer cooling Automat...

Page 9: ... for a USB connection to a PC Afterward the freeAir plus is ready for operation Button Operating the freeAir plus is so simple this button is the only control element you need Comfort selection as well as starting or stopping turbo operation is done via this button see below Press the Button multiple times to select your preferred comfort level The freeAir operation activity increases ventilation ...

Page 10: ...D will blink Yellow LED stays on indicates reduced ventilation in cases where the air quality in the Outdoor Air Room e g corridor is worse compared to the air quality in the Preferred Room e g Bedroom Blue LEDs Number of blue lit LEDs indicates selected comfort level Note Blue LEDs turn off after 3 minutes Pressing the Button will turn them back on Piep ...

Page 11: ...LED indicates a control error see chapter S Service USB Port The USB port on the right side of the freeAir is used to connect to your free copy of freeAir Connect software for updates Note For software updates visit WWW bluMartin de under service and Downloads ...

Page 12: ... freely accessible Warning Do not reach into the spinning fan Spinning blades will lead to injuries Do not stick any objects into the fan Always secure the front cover with safety screw Note For cleaning operations activate the standby operation at the DIP switch ...

Page 13: ... in the bedroom Comfort Level 3 is considered standard operation Turbo Operation If you wish to ventilate for 30 minutes at the highest power level press and hold the Button until you hear 4 short beeps Normal Comfort Operation will resume afterward Maximum power ventilation can be interrupted by pressing the Button Reset Press and hold the Button for 20 seconds until all LDS are off The freeAir p...

Page 14: ...m2 e g a gap under the door of 1 cm The side of the device with the operating element is mounted in the Outer Room The Outdoor Air Room is continuously supplied with fresh air by a freeAir 100 ventilation unit Installation site DANGER The freeAir plus must not be installed in immediate vicinity of flammable material or harmful chemicals During planning consider all relevant local building safety a...

Page 15: ...Installation 13 I Drawings ...

Page 16: ...r of 16 cm on the wall Note Technically speaking the higher up on the wall the device is installed the better the performance For optical reasons the device can also be placed lower 2 Drill the hole into the wall 3 An authorized electrician installs the connection line 3 x 1 5 mm2 in the Outdoor Air Room ...

Page 17: ...e device with the operating element is inserted in the Outdoor Air Room e g corridor Note The Outdoor Air Room is continuously supplied with fresh air by a freeAir 100 ventilation unit 5 Mark 3 drillholes for an exact horizontal position Note The both hooks for the front plate must face upwards 6 Set the drillholes precisely in both frames ...

Page 18: ...with the supplied spacers 8 An authorized electrician connects the freeAir plus with a connecting line 3 x 1 5 mm to the power supply If possible please connect all ventilation units of a housing unit to an own shared fuse 9 Activate the power supply at the fuse box only after closing of the casing ...

Page 19: ...ling When the air in the Outer Air Room is cooler than in the Preferred Room during the warmer seasons mostly at night the freeAir plus increases the airflow automatically Please select the desired temperature for the connected room Room Area m2 Please select the ventilated floor space Consider all connected rooms This indication is the basis for calculating the minimum ventilation Room Area m 2 ...

Page 20: ...itting front plate please note the foam cutting on the top of the device and pivot the plate downward until the plate is held by the magnet Note Before please set the DIP switch correctly see above in this chapter 3 Mount the front plate safety screw DANGER A missing safety screw on the front plate may cause injuries by the fan ...

Page 21: ...ences to safety and use of the freeAir plus in part General G Device Test After correct installation of the freeAir plus test the turbo operation Connect Software For checking of device functions and for possible updates we recommend laptop Windows 7 8 or 10 USB cable A plug to mini B plug our free software freeAir Connect and free updates for the freeAir plus www bluMartin de service downloads ...

Page 22: ... When you press the button thereupon the service mode is active and the blue LEDs blink Via the button now an alternative air flow of 30 m h 40 50 55 65 70 or 90 not possible during normal operation can be selected instead of the Comfort Level Note In service operation the sensor control isn t active Therefore this mode should only be used during maintenance work ...

Page 23: ...D blinks Control error The device continues to operate with the smallest volume flow The red LED is illuminated and the yellow LED flashes Please press the button for the display of the causes of error described below Note The error messages can be deleted by a reset Press the button for approx 20 seconds until the LEDs turn off ...

Page 24: ...Service S 22 Control Error Analysis 1 A control error is indicated 2 Press and hold the button ...

Page 25: ... as well as the serial number of your freeAir plus Note The reshipment of the device has to be coordinated with your service partner The device has to be shipped using the appropriate packaging ______________________ __ __ __ __ __ __ ______________________ __ __ __ __ __ __ ______________________ __ __ __ __ __ __ __ __ __ __ __ __ ______________________ __ __ __ __ __ __ ______________________ _...

Page 26: ...Service S 24 Transport Storage and Packaging Components of the freeAir plus must only be transported in the correct packaging The freeAir plus and packaging must be protected from moisture ...

Page 27: ...Service S 25 Commissioning Date Serial number Company Name Signature ...

Page 28: ...essling Germany May 2016 bluMartin GmbH Mail info bluMartin de Software Version 1 29 or newer Phone 49 8153 889033 0 All rights reserved Fax 49 8153 889033 99 Any type of copy only allowed with Web www bluMartin de the approval of bluMartin GmbH ...