![bluMartin freeair plus Operating Manual Download Page 8](http://html.mh-extra.com/html/blumartin/freeair-plus/freeair-plus_operating-manual_2778863008.webp)
General
6
[ G ]
Technical Data
Dimensions front plate
25 x 25 cm
Wall thickness
10 to 22 cm including render/ plaster
(< 12 cm with spacers supplied)
Wall breakthrough
16 cm round
Airflow rate
10 to 70 m
3
/h
Power supply
85 to 265 V AC
Mains fuse
0,315 A slow (on motherboard)
Line frequency
45 to 65 Hz
Total Power Consumption
Standby
→ 0,5 W; 30 m
3
/h
→ 0,9 W;
50 m
3
/h
→ 1,4 W; 70 m
3
/h
→ 2,5 W
Weight
3 kg
Sound pressure level
30 m
3
/h
→ 13 dB (A) (at 1 m distance);
50 m
3
/h
→ 25 dB (A);
70 m
3
/h
→ 37 dB (A);
Sound insulation factor
33 dB (EN ISO 10140-2; D
n
,
e
,
w
)
Control
Intelligent 5 level Comfort Control
Airflow control
Automatic; virtually infinitely variable
CO
2
control (VOC)
Automatic
Dehumidification
Automatic
Summer cooling
Automatic
Temperature range
0 to +40°C
Colour
Front plate primer painted (ready to paint, lacquer or design)