![Bluezone PK-220 Installation, Operation And Service Manual Download Page 20](http://html.mh-extra.com/html/bluezone/pk-220/pk-220_installation-operation-and-service-manual_2778744020.webp)
Document #: BPI-PM013-00
19
Warnings, Fault Conditions and Fault Codes
If there are issues with the operation of the PK-220, the Bluezone Logo Status Panel will
indicate the nature of the problem.
Operation status is indicated by the color of the Logo Status Panel defined in Table 3
Table 3: Bluezone Operating Status
Color
Meaning
Steady Blue
Operating Properly
Flashing Blue
(5 second on,
5 seconds off)
Order new bulbs immediately
Red
Bulbs have reached end of life and must be
replaced.
or
Operating error
Off
PK-220 is off
or
Front Panel is open
More detailed information about operating conditions are displayed on the display panel on the
side of the unit. To see this display on a ceiling mounted unit, a person must use a ladder and
lift a ceiling tile beside the unit. Fault codes and detailed operating conditions shown on the
display are described in Table
Table 4: Display Screen Status Indicator Fault Codes
Display Text
Fault
Operation
Action to Take
Interlock Open
Front Panel Open
Unit automatically
powered down.
Close Front Panel
Fan Fault
Fan not rotating
Unit automatically
powered down.
Contact Bluezone
Fault: Bulbs #-#
Bulbs not operating
Unit automatically
powered down.
Contact Bluezone
Summary of Contents for PK-220
Page 4: ...Document BPI PM013 00 3 Key Components Figure 1 Bluezone PK 220 Key Components ...
Page 11: ...Document BPI PM013 00 10 Figure 8 PK 220 Floor Mounted Figure 9 PK 220 Wall Mounted ...
Page 19: ...Document BPI PM013 00 18 Figure 15 Display Sequence in Time ...
Page 26: ...Document BPI PM013 00 25 Figure 17 Remove Service Cover Figure 18 Remove Bulb Clip Screws ...
Page 28: ...Document BPI PM013 00 27 Figure 21 Slide Bulb with Bulb Clip into the Bulb Support Bracket ...
Page 29: ...Document BPI PM013 00 28 Figure 22 Install Bulbs into Sockets Figure 23 Install Service Cover ...