Document #: BPI-PM013-00
1
IMPORTANT SAFEGUARDS
READ AND SAVE THESE INSTRUCTIONS
Safety
This manual contains important instructions
and safety information about the Bluezone Air
Purification System. Observe the following
dangers, warnings, cautions and notices
when installing, operating and servicing the
Bluezone PK-220.
Electrical System
Energized electrical circuits present a
potentially life-threatening hazard.
Ensure the unit’s power cord is unplugged
before performing any installation or service
work.
Do Not Operate unit with a damaged cord or
plug. Discard the cord and reorder a new
cord from an authorized Bluezone dealer.
Follow all lockout/tagout procedures for all
electrical circuits.
Refer to the product asset tag and confirm the
PK-220 electrical requirements before
energizing the unit.
System Operation
The appliance is not to be used by persons
(including children) with reduced physical,
sensory or mental capabilities, or lack of
experience and knowledge, unless they have
been given supervision or instruction.
Children being supervised should not play
with the appliance.
For Indoor Agricultural Applications:
Do not operate the Bluezone PK-220 while
fogging
with chlorine bleach or other
disinfectant solutions. Turn off the Bluezone
Units if disinfectant fogging or cleaning is
underway.
•
Turn Bluezone units back on after
disinfectants have dissipated.
Never hose down the Bluezone PK-220 or
clean with a water jet.
Turn off Bluezone units and cover with plastic
if the room is being hosed with water or
steam.
System Maintenance
The Bluezone PK-220 contains 4 germicidal
ultra-violet (UV-C) light bulbs; the UV light is
completely contained inside the unit during
operation.
The Bluezone PK-220 has multiple safety
systems to ensure that you cannot view the
UV bulbs while they are operating.
Do NOT attempt to override the cover switch
to allow the bulbs to operate when the cover
is off.
Skin or eye damage may result from directly
viewing the light produced by the lamp in this
apparatus. Always disconnect power before
relamping or servicing.
Replace lamps using Lamp Replacement Kit
Model No. 005-000008, manufactured by
Summary of Contents for PK-220
Page 4: ...Document BPI PM013 00 3 Key Components Figure 1 Bluezone PK 220 Key Components ...
Page 11: ...Document BPI PM013 00 10 Figure 8 PK 220 Floor Mounted Figure 9 PK 220 Wall Mounted ...
Page 19: ...Document BPI PM013 00 18 Figure 15 Display Sequence in Time ...
Page 26: ...Document BPI PM013 00 25 Figure 17 Remove Service Cover Figure 18 Remove Bulb Clip Screws ...
Page 28: ...Document BPI PM013 00 27 Figure 21 Slide Bulb with Bulb Clip into the Bulb Support Bracket ...
Page 29: ...Document BPI PM013 00 28 Figure 22 Install Bulbs into Sockets Figure 23 Install Service Cover ...