19
4)Winter Mode: Reduces the chosen Chlorine Output setting by half, for periods of low
chlorine demand during cool weather.
5)Chlorine Output: Use the left/right arrow buttons to raise/lower the system's power
setting (the rate of chlorine production), in order to customize operation for your pool's
needs.
6)Select: While in the Menu, the left/right arrows change options for Pool Temperature,
Instant Salinity, and Cell Version.
7)Menu: Press sequentially to cycle through the following information:
1.
Pool Temperature (xx degrees Fahrenheit or Celsius)
2.
Cell Voltage (in many cases 21.0 to 27.0 volts when chlorine is
being generated, otherwise 16-31V)
3.
Cell Current (in many cases 2.50 to 7.80 amps when chlorine is
being generated, otherwise 0 amps during normal rest cycles.)
4.
Real-Time Salinity reading ( xxxx ppm or x.x grams/Liter.)
5.
System ID
6.
Software revision level
7.
Cell Version.
LED INDICATOR LIGHTS:
•
Power
: Located on the Power Button, this LED indicates that the Control Unit is
receiving input power when illuminated.
•
Generate
: This LED is illuminated during normal operation, and indicates that the
system is able to generate chlorine. When flashing, the pool water is either too hot
Summary of Contents for BLSC