5
Electrolytic Cell: C
reates chlorine as the water inside passes through and returns to the
pool. The Electrolytic Cell ("Cell") contains a number of titanium plates that use a low level
of electrical power to generate chlorine from salt in the water. The Cell comes with Unions
to connect to the plumbing; each Union has a Threaded Collar that secures the Cell to the
Unions, and enables the Cell to be easily removed for cleaning and inspection purposes.
Flow Switch:
This component detect the water flow in pipe and protect the system.
WATER CHEMISTRY:
As with any pool, it is important that you maintain proper water chemistry of the pool water,
including pH, alkaline content, and calcium levels. The only special requirement for BLSC
is to maintain proper levels of salt and stabilizer. It is important to maintain these levels in
order to prevent corrosion or scaling and to ensure maximum enjoyment of the pool. Test
your water periodically. It is recommended that pool water be professionally tested a
minimum of twice per season. Your local pool store can provide you with the chemicals
and procedures to adjust the water chemistry. Be sure to tell the pool store that you are
using a salt chlorine generator.
IDEAL CHEMICAL LEVELS
Swimming Pools
Spas
Free chlorine
1.0 to 3.0 ppm
3.0 to 5.0 ppm
Salinity
3000 to 4000 ppm
3000 to 4000 ppm
pH
7.2 to 7.8
7.2 to 7.8
Cyanuric Acid (Stabilizer)
60 to 80 ppm
60 to 80 ppm
Total Alkalinity
80 to 120 ppm
80 to 120 ppm
Calcium Hardness
200 to 400 ppm
150 to 450 ppm
Saturation Index
-0.2 to 0.2
-0.2 to 0.2
Summary of Contents for BLSC
Page 1: ...BLSC ...