BVC6100LM Instruction Manual v.01
- 21 -
6.1,1 Operation mode
Camera sync mode and Exposure are set by 「Trigger」、「Source」、「Polarity」
Possible combination for Sync and Exposure
Trigger
Source
Polarity
動作内容
Sync
mode
Exposure
NoShutterMode
invalid
invalid
Internal
By line cycle
ShutterSelectMode
ExternalTriggerOF
F
invalid
Internal
By
channel
exposure control
ShutterSelectMode
ExternalTriggerON Actvie Low/Active
Hgih
External By
channel
exposure control
PWC Mode
ExternalTriggerON Actvie Low/Active
Hgih
External By trigger width
Setting procedure
「Trigger」: select trigger mode
No Shutter Mode : Only for Internal sync, Exposure time= Line cycle time.
Shutter Select Mode :
The exposure is set for R,G ,B, IR channels individually.
In this mode, as the end of the exposure for each channel coincides, the exposure will start
from the channel having the longest exposure time.
Other channels start with some delay so that the end of the exposure coincides.
Exposure time should set within line cycle in Internal sync.
Exposure time should set within external trigger cycle in External sync.
PWC Mode :
The exposure for each channel is controlled by the trigger pulse.
The exposure time is always the same for 4 channels.
「Source」: select trigger signal
External Trigger OFF : Internal sync mode
Line rate is set by Line rate setting part.
External Trigger CC1 : Cameralink cc1 is selected as External trigger
External Trigger DCIN : DCIN is selected as External trigger