4  Preparation of the BlueVary via the menu  

 

General explanations 

4.1
 
The 

BlueVary

  has  an  integrated  keypad  and  a  LCD  display  for 

showing values and changing settings. To indicate the selected line a 
„-„ [cursor] is displayed in front of the text of the line (see fig. 5).  

 

The functions of the keypad are: 

: Moves the curser upwards / increases values 

: Moves the curser downwards / decreases values 

: Moves the curser to the left 

: Moves the curser to the right 

OK: Input acknowledgement / selections 

esc: End of input / back to last level 

 

 

 

 

Glossary of the pictures: 

Bold

 type lines are for input or to make a choice. 

The keypad is 

Bold

 type within the text: 



 



 OK esc

Menu items are displayed 

italic

 within the text. 

To select a menu item move the cursor with 



 

to the corresponding line and press

 Ok

 

For options, these are selected via 



, numbers are entered via 



 



 

To finish an input press the 

esc

 – button. 

To store values, it is necessary to select the menu item Apply settings.  

Should a menu to be left, always can be pressed the 

esc

 – button. 

 

 

Fig. 5:Available buttons on the 

BlueVary

     

Center. 



 



 OK esc

 

Summary of Contents for BlueVary

Page 1: ...EN DE Updating Manual multilingual BlueVary...

Page 2: ...EN Updating Manual BlueVary...

Page 3: ...NSTALLATION 5 General instructions 5 3 1 Electrical connection 5 3 2 3 2 1 General information 5 3 2 2 Power up 6 3 2 3 Connection via RS232 USB 6 4 PREPARATION OF THE BLUEVARY VIA THE MENU 7 General...

Page 4: ...sonnel The content of this manual must be made available to the corresponding personnel and followed by them Symbols used 1 3 Hazard This symbol indicates a possibly hazardous situation Failure to obs...

Page 5: ...this manual and the operation manual may only be performed by personnel of the BlueSens gas sensor GmbH company for safety reasons and to ensure compliance with the terms of the guarantee Proper use 2...

Page 6: ...erials such as gaskets are suitable for your process conditions pressure temperature etc The installation should only be performed under supervision by a specialist and in compliance with all applicab...

Page 7: ...l connection RS232 to USB fig 4 1 Connect cable D to the corresponding connector of cable C 2 Plug in the USB adapter into a free USB port of your computer Be aware that the USB adapter does not repla...

Page 8: ...left Moves the curser to the right OK Input acknowledgement selections esc End of input back to last level Glossary of the pictures Bold type lines are for input or to make a choice The keypad is Bol...

Page 9: ...shows the gas type and concentration of the attached cartridges followed by the pressure and the absolute humidity It also shows the lifetime of the attached cartridges Pressing OK will lead you to t...

Page 10: ...wer up user level always switches to Normal User To prepare the BlueVary for the firmware update the Admin has to be selected Place the cursor with the buttons in front of the Admin By pressing OK but...

Page 11: ...pdate the item Read new firmware has to be selected and press OK On the new screen that comes up Fig 11 Reset has to be selected and press OK The BlueVary now will execute a reset to start the firmwar...

Page 12: ...exe Both can be received from the BlueSens service team Preparing the software 5 1 The firmware and the update program are normally provided as a zip file containing a folder with the latest firmware...

Page 13: ...s to be marked After closing the program again reconnecting the adapter to the same USB port as before and opening the program again this port has to be chosen If the BlueVary is in firmware update mo...

Page 14: ...destroy the BlueVary The updating of the firmware will take less than 2 minutes It is performed in two different steps First the old firmware will be erased Fig 17 Then the new firmware is uploaded Fi...

Page 15: ...it To free the COM port for other application the Disconnect button has to be pressed Fig 19 Now the program has to be closed or another BlueVary has to be connected to the RS232 USB adaptor Please be...

Page 16: ...If necessary please contact your distributor or directly to us Tel 49 2366 4995 567 or via e mail service bluesens de USA 847 201 3124 or via e mail service bluesens com Imprint 6 3 BlueVary Update M...

Page 17: ...DE Updat Manual multilingual BlueVary...

Page 18: ...se 4 3 INSTALLATION 5 3 1 Allgemeine Hinweise 5 3 2 Elektrischer Anschluss 5 3 2 1 Allgemeine Informationen 5 3 2 2 Einschalten 6 3 2 3 Anschluss ber RS232 USB 6 4 VORBEREITUNG DES BLUEVARY BER SEIN M...

Page 19: ...nleitung muss dem entsprechenden Personal zur Verf gung gestellt und von diesem befolgt werden 1 3 Verwendete Symbole Gefahr Dieses Symbol weist auf eine m gliche Gefahrensituation hin Die Nichtbeacht...

Page 20: ...Bedienungsanleitung beschrieben sind d rfen aus Sicherheitsgr nden und zur Sicherstellung der Einhaltung der Garantiebedingungen nur von Personal der Firma BlueSens Gassensor GmbH durchgef hrt werden...

Page 21: ...ungen f r Ihre Prozessbedingungen Druck Temperatur usw geeignet sind Die Installation sollte nur unter Aufsicht eines Fachmanns und unter Einhaltung aller geltenden Arbeitssicherheitsvorschriften durc...

Page 22: ...tigt Abb 4 1 Kabel D an den entsprechenden Stecker des Kabels C anschlie en 2 Stecken Sie den USB Adapter in einen freien USB Anschluss Ihres Computers Beachten Sie dass der USB Adapter die Stromvers...

Page 23: ...or nach rechts OK Eingabebest tigung Auswahl esc Ende der Eingabe zur ck zur letzten Ebene Glossar der Abbildungen Fett gedruckte Zeilen dienen zur Eingabe oder zur Auswahl Die Tastatur ist im Text fe...

Page 24: ...die Gasart und konzentration der angeschlossenen Kartuschen an gefolgt vom Druck und der absoluten Luftfeuchtigkeit Sie zeigt auch die verbleibende Lebensdauer der angeschlossenen Kartuschen an Mit OK...

Page 25: ...ormaler Benutzer Um ein Firmware update durchf hren zu k nnen muss als Benutzer Admin ausgew hlt werden Positionieren Sie zuerst den Cursor mit den Tasten vor den Admin Benutzer Durch Dr cken der OK T...

Page 26: ...re Neue Firmware lesen durch und dr cken Sie die OK Taste ausgew hlt werden Anschlie end muss Reset durch und dr cken Sie die OK Taste ausgew hlt werden Nun f hrt der BlueVary einen Reset durch um in...

Page 27: ...exe genutzt werden Beides kann vom BlueSens Service Team bezogen werden 5 1 Vorbereitung der Software Die Firmware und das Updateprogramm werden normalerweise als zip Datei ausgeliefert Diese enth lt...

Page 28: ...neutem schlie en des Programm verbinden des Adapters am gleichen USB Anschluss und anschlie enden starten des Programms muss dieser COM Port ausgew hlt werden Wenn der BlueVary im Firmware Update Modu...

Page 29: ...hren Das Firmware Update ben tigt weniger als 2 Minuten Es wird in mehreren Schritten durchgef hrt Als erstes wird die alte Firmware gel scht Abb 17 Anschlie end wird die neue Firmware geladen Abb 18...

Page 30: ...andere Programme frei zu geben muss die Disconnect Taste gedr ckt werden Abb 19 Zum Abschuss kann das Programm beendet werden oder es kann ein weitere BlueVary an den RS232 USB Adapter angeschlossen w...

Page 31: ...bitte an Ihren H ndler oder direkt an uns Tel 49 2366 4995 567 oder per E Mail an service bluesens de USA 847 201 3124 oder per E Mail an service bluesens com 6 3 Impressum BlueVary Update Anleitung d...

Reviews: