AlcoTrue® E - Operating instructions | bluepoint® MEDICAL GmbH & Co. KG 2014  

6

 

3. Device 

 

 
3.1 AlcoTrue® E – device components 
 
 

 

         

         

 

       

       Front view  

    Side view 

      Rear view 

 
 
 

 

No. 

Description 

No. 

Description 

 

Display    

 

Device inlet 

 

Menu 

 

 

Device outlet 

 

“ON/OFF/Confirm” button 

 

 

Device label 

 

Background light 

 

 

Battery compartment lid 

 
 
 
 
 

3.2 Device label-symbols 

 

Consult 

user 

manual 

for 

detailed operating instructions! 

 

Serial number 

 

CE certified to 89/336/EWG 

 

Product number 

 

Manufacturer 

 

Observe disposal regulations! 

 

 
 
 
 
 
 
 
 
 
 


 

Summary of Contents for AlcoTrue E

Page 1: ...AlcoTrue E Operating instructions bluepoint MEDICAL GmbH Co KG 2014 1 Operating instructions AlcoTrue E Breathalyser for personal use...

Page 2: ...em to be free from faulty materials and workmanship for a period of 15 months from date of original shipment to first end user except for wear parts disposable products or products which have a stated...

Page 3: ...y level indications 7 5 Device switch ON OFF 7 6 Carrying out the measurement 9 6 1Before measuring 9 6 1 1 Requirements of the person to be tested 9 6 1 2 Conditions 9 6 1 3 Inserting the mouthpiece...

Page 4: ...rk must be carried out by authorised service personnel only Only original parts from bluepoint MEDICAL GmbH Co KG may be used for repairs Only the accessories specified in the order list shall be used...

Page 5: ...similar kind of pre test breathalysers are not a evidential proof of for example prior a court suitable With AlcoTrue E usage it can only serve to confirm an initial suspicion Calibration AlcoTrue E...

Page 6: ...ription No Description Display Device inlet Menu Device outlet ON OFF Confirm button Device label Background light Battery compartment lid 3 2 Device label symbols Consult user manual for detailed ope...

Page 7: ...Close battery cover Use only 3 x 1 5V Type Alkaline Mignon LR6 AA Never mix batteries of different brands and different discharge levels Always replace all batteries at once Remove the batteries if th...

Page 8: ...surements self test till new calibration is required Automatic switch off AlcoTrue E switches off automatically approx 3 minutes after the last use Switch OFF Keep button pressed countdown is displaye...

Page 9: ...st be ensured that the test person has not been smoking before performing the measurement A waiting period of at least 5 minutes after smoking must be observed A required minimum breath volume must be...

Page 10: ...sampling the follow display is showing Alcohol breat test is successful when breathing volume and blowing time are reached beep tone stops Press button for a new measurement Insert a new mouthpiece i...

Page 11: ...shown The display flashes Cal To scroll through the indicated unit press on the button To select a unit press the button With the button you can turn on off the backlight Continuously usage of the ba...

Page 12: ...ery compartments must remain dry to ensure proper function of AlcoTrue E Calibration The period of calibration validity is 1000 measurements or 12 months after calibration period expires the device wi...

Page 13: ...nditions Turn on device Ambient temperature is lower than 5 Turn off device Bring device within specified operating conditions Turn on device pressure sensor error Start device again If the fault occu...

Page 14: ...00 to 1 08 mg L BrAC 0 to 108 g 100mL Ethanol mass per breath volume at 34 C and 1013 hPa Blood alcohol concentration 0 00 to 2 50 BAC 0 000 to 0 250 0 00 to 2 50g L 0 to 250 mg 100mL Ethanol mass pe...

Page 15: ...ng a measurement in range BAC Typ 0 00 2s 1 00 15s Mouthpiece type Typ S from bluepoint Medical GmbH Co KG Calibration interval 1000 measurements or 12 months Calibration type Wet gas Permissible cali...

Page 16: ...atteries 3 x 1 5V Type Alkaline Mignon LR6 AA Typ 2000 measurements at room temperature Display 1 8 black white LCD with LED background light Data memory CE marking Standards EN 61326 1 2006 designed...

Page 17: ...point MEDICAL GmbH Co KG All Rights Reserved No part of this document may be photocopied reproduced or translate to another language without prior written consent of bluepoint MEDICAL GmbH Co KG bluep...