20
Shenyang Bluelight Automatic Technology Co., Ltd.
BL6-DU20PX series Integrated Door Motor Controller User Manual
Chart 5.2 Function Detail List (Cont’d)
Function
Code
Name
Setting Range
Min Unit
Factory
Default
Setting
Group F6 Distance Control Parameters
F600
Door Width Self-Tune
Function Select
0: Invalid
1: Door Width Measurement,
Valid in Manual Mode of Door
Motor Controller
1
0
F601
Door Width Self-Tune
Speed
0~20.00Hz
0.01Hz
3.00Hz
F602
Door Width Pulses Low Bits
0~9999
1
0
F603
Door Width Pulses High Bits
0~9999
1
0
F604
Distance Control Door-open
Start Low-speed Running
Distance
0~30.0%(Door Width)
0.1%
10.0%
F605
Distance Control Door-open
Deceleration Point
60.0%~90.0%(Door Width)
0.1%
70.0%
F606
Distance Control Door-open
Limit Point
80.0%~99.0% (Door Width)
0.1%
96.0%
F607
Distance Control Door-close
Start Low-speed Running
Distance
0%~30.0% (Door Width)
0.1%
10.0%
F608
Distance Control Door-close
Deceleration Position
60.0%~90.0%(Door Width)
0.1%
70.0%
F609
Distance Control Door-close
Limit Position
80.0%~99.0% (Door Width)
0.1%
93.0%
F610
Door-open Limit Switch
Position Low Bits
0~9999
1
0
F611
Door-open Limit Switch
Position High Bits
0~9999
1
0
F612
Door-close Limit Switch
Position
0~9999
1
0
F613
Door Width Self-tune &
Initial Running Torque
0~300.0%
0.1%
120.0%
F614
Door-open Deceleration
Point Pulses Low Bits
0~9999
1
0
F615
Door-open
Deceleration
Point Pulses High Bits
0~9999
1
0
F616
Door-close
Deceleration
Point Pulses Low Bits
0~9999
1
0
F617
Door-close
Deceleration
Point Pulses High Bits
0~9999
1
0
F618
Door Open to the Limit
Output Door Width
0~99.99%
0.1%
96.0%
F619
Door Close to the Limit
Output Door Width
0~99.99%
0.1%
6.0%
F620
Door Position Feedback
Pulses
0~99.99%
0.1%
6.0%