13
Shenyang Bluelight Automatic Technology Co., Ltd.
BL6-DU20PX series Integrated Door Motor Controller User Manual
C
HART
4.2
K
EY
F
UNCTION
D
ESCRIPTIONS
Key
Name
Function
PRG
Program
Enter function group menu or back to main menu
ENT
Enter
Enter function code menu/parameter saving menu, or
save setting parameters
STOP/RES
Stop/Reset
In running status, press this key to stop running;
In fault status, press this key to reset fault.
Right move
In main menu, show parameter;
In parameter menu, move cursor.
Increase
Data or function codes increase.
Decrease
Data or function codes decrease.
OPEN
Open Door
Operation on panel when F002=1, open the door.
CLOSE
Close Door
Operation on panel when F002=1, close the door.
4.2
Operation
4.2.1
Menu Operation Process
The menu structure of BL6-DU20PX series integrated door motor controller operation panel,
has been divided to several group according to function. Each group includes several function codes.
Enter each function code, then check or modify parameter setting. The operation process is show in
figure 4.2.
15.00
F0
F001
15.00
PRG
PRG
ENTER
ENTER
PRG
PRG/
ENTER
Modify Parameter Group
Modify Function Code
Modify Function
Code Value
F
IGURE
4.2
M
ENU
O
PERATION
P
ROCESS
Note: When operating parameter modification, press ENTER to save and switch to next
function code; Pressing PRG will not save parameter and will directly return to parameter group
menu.
For example, modify the function code F005 from 0 to 34. (The bit in bold type is modifiable.)