Chart 5.2 Function Detail List (Cont’d)
Function
Code
Name
Setting Range
Min Unit
Factory
Default
Setting
Group F5 Door Control Auxiliary Parameters
F500
Abnormal Deceleration
Time
0~5.0s
0.1s
0.2s
F501
Door Open Time Limit
0~999.9s
0.1s
30.0s
F502
Door Close Time Limit
0~999.9s
0.1s
30.0s
F503
Low speed Running Time
Limit
0~999.9s
0.1s
50.0s
F504
External Door-open
Instruction Delay
0~999.9s
0.1s
15.0s
F505
External Door-close
Instruction Delay
0~999.9s
0.1s
15.0s
F506
Speed Deviation Setting
0~80.0%
0.1%
30.0%
F507
Large Speed Deviation
Determination Time
0~5000ms
1ms
100ms
F508
Door-close Stable Speed
Delay
0~9999ms
1ms
200ms
F509
Door-open S Curve
Select
0: Straight Line
1: S Curve
0
1
F510
Door-close S Curve
Select
0: Straight Line
1: S Curve
0
1
F511
Door-open Acceleration S
Curve Start Time
10.0%~40.0%
0.1%
20.0%
F512
Door-open Acceleration S
Curve End Time
10.0%~40.0%
0.1%
20.0%
F513
Door-open Deceleration S
Curve Start Time
10.0%~40.0%
0.1%
20.0%
F514
Door-open Deceleration S
Curve End Time
10.0%~40.0%
0.1%
20.0%
F515
Door-close Acceleration S
Curve Start Time
10.0%~40.0%
0.1%
20.0%
F516
Door-close Acceleration S
Curve End Time
10.0%~40.0%
0.1%
20.0%
F517
Door-close Deceleration S
Curve Start Time
10.0%~40.0%
0.1%
20.0%
F518
Door-close Deceleration S
Curve End Time
10.0%~40.0%
0.1%
20.0%
F519
Motor Self-tune Torque
0.0%~20.0%
0.1%
1.0%
F520
Motor Angle Self-tune
0~1
1
0