32
33
WARNING
- Level sensor may not operate properly due to water condition or sediment inside of the
sensor.
For proper operation of Level sensor, clean the sediment inside of the sensor often.
- Level Sensor should be cleaned at least once a month.
(Recommended cleaning period can be shorter due to the condition of water.
4.3 Level Sensor Cleaning
1) Refer to “2.5 How to Remove Panel”, to separate the Ice Cover from body
2) In order to drain out water inside the cabinet completely, detach Pump Hose as shown in the mage.
3) Disassemble Level Sensor refer to “Front Cover” in the Removal and replacement chapter.
4) Separate the parts in order of Connector, Stopper, Float, and Body referring to image.
5) Wash contamination inside of Connector and Body.
6) Reassemble Level Sensor in reverse order.
7) Reassemble front panel.
Pump Hose
Body
Stopper
Level Sensor Connector
Float
Fig 7
Summary of Contents for BLMI-300A
Page 1: ...InstallationandUser sManual BLMI 300A BLMI 500A BLMI 650A BLMI 900A ver 201803_02 I512A 200 ...
Page 7: ...1 2 Product Dimensions 300A 500A 7 FRONT TOP SIDE REAR ...
Page 8: ...8 650A FRONT TOP SIDE REAR ...
Page 9: ...9 900A FRONT TOP SIDE REAR ...
Page 34: ...MEMO 34 ...
Page 35: ...MEMO 35 ...