Congratulations on your purchase on a APNTU Turbidity 
water analyzer!  

The APNTU Analyzer Panel is specifically designed as a ‘Turn-Key’ monitor-

ing solution for clean water applications including drinking water networks, 

secondary water supply and decorative/swimming water applications. 

The APNTU series offers highly accurate, real-time measurement, display 

and data-logging of Ultra-Low Turbidity utilizing proprietary smart sensor 

technology, coupled with a touch screen display and data logging terminal. 

Reference the below dimensional drawings for installation. 

APNTU Panel Dimensions

7 inch touch screen

WR10

Turbidity Sensor

Water Outlet 3/4” ID

Drain Valve

3/8” OD

Flowmeter

Pressure Regulating Valve

A

B

C

D

E

Water Inlet

1/4” OD

Dim

Inch

cm

A

20.00”

50.8

B

36.00”

91.4

C

9.42”

23.9

D

7.80”

19.8

E

4.98”

12.6

Note: Strut spacing is 15” 

centerline to centerline.

Summary of Contents for APNTU

Page 1: ...Quick Start Guide APNTU Turbidity Analyzer Panel...

Page 2: ...l time measurement display and data logging of Ultra Low Turbidity utilizing proprietary smart sensor technology coupled with a touch screen display and data logging terminal Reference the below dimen...

Page 3: ...trical Schematics Quick Start Guide Tools Needed Follow these instructions before installing your analyzer to avoid failure Read this guide and Instruction Manual before using CAUTION The APNTU is des...

Page 4: ...g to the outlet drain This is the sample water outlet flow This line must be diverted to drain Wall Mount Space The APNTU analyzer panel size is roughly 20 H x 36 W x 10 D in dimension Please accommod...

Page 5: ...e and clean thoroughly Located strut and mount with appropriate tools Check to make sure strut is secure and level 2 4 Connect Electrical and Tubing Use provided electrical diagram to connect power an...

Page 6: ...y necessary when changing parameter settings or performing calibrations To access this now press the icon and refer to Instruction Manual for more instructions regarding login and user management Real...

Page 7: ...U USB 1 x USB host for data downloading and screen upgrade Internet RJ 45 socket Modbus TCP Panel Operational Temperature 40 113o F 4 45 o C Storage Temperature Instrument 4 131o F 20 55o C Sensors 32...

Page 8: ...ssive heat or pressure or allowing the unit to support the weight of related piping BLUE WHITE does not assume responsibility for any loss damage or expense directly or indirectly related to or arisin...

Reviews: