5.2 Wall Mounting
1. Using the provided #10 self-tapping screws, mount the bracket to a secure wall that is located where it can be
easily serviced.
#10 Self-Tap
(2 X)
4.50 in.
[11.43 cm]
Page 10
Wall Mount Bracket (Side View)
Mounted Pump (Front View)
2. Lower the pump so that the tab on the wall mount is inserted into the slot located on the back of the pump. The
pump will now be secured to the wall mount bracket.
Wall Mount Tab
Wall mount slot
Wall Mount (Side View)
Mounted Pump
®
FlexFlo A1A
Pipe Tee
1/2” male NPT
1/4” male NPT
Weight,
Ceramic
Suction tubing, PVC
3/8" (0.95 cm) O.D. X
1/4” (0.64 cm) I.D.
Strainer,
Polypropylene
Polypropylene
Spring, Hastelloy C-276
Polypropylene
O-ring, TFE/P (optional EP)
Ball, Ceramic
O-ring, TFE/P (optional EP)
Polypropylene
Injection nose
may be trimmed
(removed) when
injecting into
small pipe.
Install upward
for best results.
Assemble the injection fitting and strainer per the figures below.
NOTE
: Install upward for best results.
NOTE
: The injection nose may be trimmed (removed) when injecting into a small pipe.
Proper eye and skin protection must be worn when installing and servicing pump.
!
CAUTION
INJECTION FITTING AND STRAINER FOR 1/4” (0.64 CM) I.D. CONNECTION END MODELS
Discharge Injection Fitting / Check Valve
Suction Tubing and Strainer
Page 11
5.3
Installing Injection Fitting and Strainer
®
FlexFlo A1A
Summary of Contents for FLEXFLO A1A Series
Page 3: ...READ THE INSTRUCTION MANUAL PRIOR TO INSTALLATION AND USE Page 3 FlexFlo A1A...
Page 25: ...Page 25 FlexFlo A1A THIS PAGE IS LEFT INTENTIONALLY BLANK...
Page 30: ...Page 30 THIS PAGE IS LEFT INTENTIONALLY BLANK FlexFlo A1A...
Page 31: ...Page 31 THIS PAGE IS LEFT INTENTIONALLY BLANK FlexFlo A1A...