15
Operation
Re-Setting the Overtemp Device (All UK and Optional Non-UK Models).
This griddle is fitted
with an overtemp device which isolates the gas supply to the burners should the gas
control system or thermostat malfunction, thus preventing overheating of the griddle. If the pilot fails to
ignite after several attempts, ensure that the overtemp is checked to ensure that it has not tripped.
1.
To reset the overtemp, remove the gas
control knobs from the front of the
griddle. These are a push fit onto the
spindle of the gas valves.
2.
Slacken the 2 screws securing the front
control panel to the front of the griddle
and carefully remove the control panel,
ensuring that the leads to the piezo
igniter are disconnected from the rear
of the piezo buttons.
3.
Using a small screwdriver, depress the
centre of the overtemp reset button.
4.
Re-connect the piezo igniter leads to
the rear of the piezo igniter buttons.
5.
Refit the front control panel onto the griddle and secure in position with the 2 securing screws.
6.
Refit the gas control knobs to the gas spindles.
7.
Attempt to re-light the pilot burners as shown above. Should the pilot burners still not ignite, call a
qualified service person to investigate the problem.
For the Refrigeration Cabinet Operation refer to the Refrigeration Cabinet Installation and
Operation Manual supplied with the appliance.
Overtemp fitted to
Gas Control Valve.
O v e r t e m p
reset button
Fig 4
Should any abnormal operation like;
- ignition problems,
- abnormal burner flame,
- burner control problems,
- partial or full loss of burner flame in normal operation, be noticed, the appliance requires
IMMEDIATE service by a qualified service person and should not be used until such service is
carried out.