20
8.
Refit the front control panel and tighten the 2 screws on the underside to secure the panel in place.
9.
Refit the control knobs to the front control panel. The control knobs are a push fit onto the shafts of
the gas control valves.
Low Fire Adjustment - (Gas Griddle)
To change the gas griddle thermostat ‘Low Fire’ adjustment, the low fire screw on the gas control valve
should be screwed fully in, then unscrewed by 1 full turn as shown in the ‘Gas Specifications’ table at the
end of this section.
1.
Remove the griddle gas control knob
from the front control panel. The knob
is a push fit onto the shaft of the gas
control valve.
2.
Remove the gas griddle control panel
from the front of the gas griddle by
removing the 2 securing screws in the
lower corners of the panel.
3.
Screw the ‘Low Fire’ screw fully ‘IN’ and then unscrew by
1 Full Turn
of the ‘Low Fire’ screw.
(Refer to the ‘Gas Specification’ table at the rear of this section).
4.
Ensure that the Gas Control Pilot Screw is adjusted to 3 turns out c.c.w.
5.
Refit the control panel and secure with the securing screws.
6.
Refit the gas control knob to the shaft of the gas control valve.
NOTE: The ‘Low Fire Screw’ should be sealed with coloured paint on completion of the low fire
adjustment.
Gas Conversion and Specifications
Low Fire
Adjustment Screw
Gas Control
Pilot Screw
Fig 8