4
Specifications
Gas Supply Requirements
- Australia / New Zealand Only:
- UK Only:
Appliance Classification
Category:
II
2H3P.
Flue Type:
A
1.
*
The burner operating pressure is to be measured at the gas control valve outlet test point (Refer
to Fig 2) with one griddle burner operating at ‘High’ setting. The operating pressure is
ex-factory set, through the appliance regulator and not to be adjusted, apart from when
carrying out gas conversion, if required. (Refer to the ‘Gas Conversion’ section for details).
Gas Connection
Gas supply connection point is located 130mm from the right hand side of the appliance, 35mm from
the rear and 655mm from the floor and is entered from beneath the appliance. An optional
underside connection is available.
Connection is ¾” BSP male.
For the Refrigeration Cabinet Specifications refer to the Refrigeration Cabinet Installation and
Operation Manual supplied with the appliance.
Natural Gas (G20)
Propane (G31)
GP514
GP516
GP518
GP514
GP516
GP518
Heat Input (nett)
13.3 kW
21 kW
28.5 kW
13.3 kW
21 kW
28.5 kW
Gas Rate (nett)
1.41 m
3
/hr
2.22 m
3
/hr 3.02 m
3
/hr
1.03 kg/hr 1.63 kg/hr 2.21 kg/hr
Supply Pressure
20 mbar
37 mbar
Burner Operating
Pressure
8.5 mbar (*)
8.2 mbar (*)
Gas Connection
3
/
4
” BSP Male
26 mbar (*)
Natural Gas
LP Gas (Propane)
GP514
GP516
GP518
GP514
GP516
GP518
Input
Rating
53 MJ/hr
(50,234 Btu)
80 MJ/hr
(75,825 Btu)
108 MJ/hr
(102,364 Btu)
53 MJ/hr
(50,234 Btu)
80 MJ/hr
(75,825 Btu)
108 MJ/hr
(102,364 Btu)
Supply
Pressure
1.13 - 3.40 kPa
(4.5” - 13.5” w.c.)
2.75 - 4.50 kPa
(11” - 18” w.c.)
Operating
Pressure
0.85 kPa (
*
)
(3.4” w.c.)
0.90 kPa (
*
)
(3.6” w.c.)
2.5 kPa (
*
)
(9.8” w.c.)
Gas
¾” BSP Male
2.6 kPa (
*
)
(10.2” w.c.)