background image

GAS GRIDDLE 

 GP514 

 GP516 
 GP518 

I N S T A L L A T I O N   A N D   O P E R A T I O N   M A N U A L  

229284-8 

For use in GB & IE 

 

Summary of Contents for Evolution GP514

Page 1: ...GAS GRIDDLE GP514 GP516 GP518 I N S T A L L A T I O N A N D O P E R A T I O N M A N U A L 229284 8 For use in GB IE ...

Page 2: ...61 0257 Fax 336 661 9546 CANADA Serve Canada 22 Ashwarren Road Downview Ontario M3J1Z5 Toll Free 800 263 1455 Ph 416 631 0601 Fax 416 631 0315 info servecanada com www servecanada com www moffat com NEW ZEALAND Christchurch Auckland Moffat Limited Moffat Limited PO Box 10 001 4 Waipuna Road 16 Osborne Street Mt Wellington Christchurch Auckland Ph 03 389 1007 Ph 09 574 3150 Fax 03 389 1276 Fax 09 5...

Page 3: ...sions 5 Installation 9 Installation Requirements Unpacking Location Clearances Assembly Gas Connection Commissioning Operation 12 Operation Guide Description of Controls Lighting the Pilot Burner Lighting the Main Burner Cleaning and Maintenance 15 Routine Maintenance After Each Use Daily Cleaning Weekly Cleaning Fault Finding 18 Gas Conversion and Specifications 19 Conversion Procedure Gas Specif...

Page 4: ... THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE WARNING INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT LOCATION THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER WARNING GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF...

Page 5: ...riddle 1200mm wide with Refrigerated Base General A commercial heavy duty fully modular gas fired griddle using a thermostatic burner system and fitted with aluminised steel burners with full pilot and flame failure protection and piezo ignition It uses a 20mm thick griddle plate with the option of either ribbed or chromed mirror plate options All UK Models and optional Non UK models are fitted wi...

Page 6: ...nal underside connection is available Connection is BSP male For the Refrigeration Cabinet Specifications refer to the Refrigeration Cabinet Installation and Operation Manual supplied with the appliance Natural Gas G20 Propane G31 GP514 GP516 GP518 GP514 GP516 GP518 Heat Input nett 13 3 kW 21 kW 28 5 kW 13 3 kW 21 kW 28 5 kW Gas Rate nett 1 41 m3 hr 2 22 m3 hr 3 02 m3 hr 1 03 kg hr 1 63 kg hr 2 21...

Page 7: ...5 Dimensions GP514 B GP516 B GP518 B Dimensions for Bench Models Rating Plate Location for this option R R ...

Page 8: ...6 Dimensions GP514 CB GP516 CB GP518 CB Dimensions for Cabinet Base Models Rating Plate Location for this option R R ...

Page 9: ...7 Dimensions GP514 LS GP516 LS GP518 LS Dimensions for Leg Stand Models Rating Plate Location for this option R R ...

Page 10: ...8 Dimensions GP516 RB GP518 RB Dimensions for Refrigeration Base Models Rating Plate Location for this option R R 280 ...

Page 11: ...ppliance including all protective plastic coating from the exterior stainless steel panels Check equipment and parts for damage Report any damage immediately to the carrier and distributor Ensure that the 4 adjustable feet are fitted with the protruding centre screw Report any deficiencies to the distributor who supplied the appliance Check that the available gas supply is correct to that shown on...

Page 12: ...installed for The gas conversion procedure is detailed in this manual b Supply Pressure required for this appliance is shown in the Specifications section of this manual Check the gas supply to ensure adequate supply pressure exists c Input Rate of this appliance is stated on the Rating Plate refer to the Dimensions section for rating plate locations for the different models The input rate should ...

Page 13: ...as supply and the appliance 10 Verify the operating pressure remains correct Commissioning 1 Before leaving the new installation a Check the following functions in accordance with the operating instructions specified in the Operation section of this manual Light the Pilot Burner Light the Main Burner Turning Off the Main Burner Pilot b Ensure that the operator has been instructed in the areas of c...

Page 14: ...ing sections carefully Lighting the Pilot Burner Lighting the Main Burner Turning Off the Main Burner Pilot Description of Controls Gas Griddle Controls Piezo Igniter with Viewing Hole OFF Position PILOT Burner Temperature Gradient CAUTION This appliance is for professional use and is only to be used by qualified people Only qualified service persons are to carry out installation servicing or gas ...

Page 15: ...e gas control knob anti clockwise to the desired temperature marked on the gas control knob 3 The main burner will now ignite automatically off the pilot burner Re Setting the Overtemp Device All UK and Optional Non UK Models This griddle is fitted with an overtemp device which isolates the gas supply to the burners should the gas control system or thermostat malfunction thus preventing overheatin...

Page 16: ...will extinguish and the pilot burner will remain alight 2 To turn OFF the appliance completely turn the gas control knob fully clockwise to the O position the pilot burner will extinguish For the Refrigeration Cabinet Operation refer to the Refrigeration Cabinet Installation and Operation Manual supplied with the appliance ...

Page 17: ...re cleaning NOTE DO NOT use abrasive detergents strong solvents or caustic detergents as they could corrode or damage the griddle In order to prevent the forming of rust on the griddle plate Steel Plate ensure that any detergent or cleaning material has been completely removed after each cleaning The appliance should be switched on briefly to ensure the griddle plate becomes dry Oil or grease shou...

Page 18: ...le Steel Plate NOTE In order to prevent the forming of rust on the griddle plate ensure that all detergent and cleaning material has been entirely removed after each cleaning process The appliance should be switched on briefly to ensure the griddle plate becomes dry Oil or grease should be spread over the griddle surface in order to form a thin protective greasy film a Remove and clean the grease ...

Page 19: ...te that the gas control knobs are a push fit onto the gas control valve spindles and can be removed to allow cleaning of the front control panel b Baked on deposits or discolouration may require a good quality stainless steel cleaner or stainless steel wool Always apply cleaner when the appliance is cold and rub in the direction of the grain c To remove any discolouration use an approved stainless...

Page 20: ...are not to be adjusted by an unqualified service person This section provides an easy reference guide to the more common problems that may occur during the operation of your equipment The fault finding guide in this section is intended to help you correct or at least accurately diagnose problems with your equipment Although this section covers the most common problems reported you may encounter a ...

Page 21: ...s from the rating plate affixed behind the front control panel and on the inner face of the right hand panel 6 Replace with the correct size injectors Refer to Gas Specifications Table for injector sizes Pilot Burners 1 To remove the pilot burner injector disconnect the lead to the piezo igniter and unscrew the piezo igniter from the mounting bracket this is precautionary to prevent damage to the ...

Page 22: ...el The knob is a push fit onto the shaft of the gas control valve 2 Remove the gas griddle control panel from the front of the gas griddle by removing the 2 securing screws in the lower corners of the panel 3 Screw the Low Fire screw fully IN and then unscrew by 1 Full Turn of the Low Fire screw Refer to the Gas Specification table at the rear of this section 4 Ensure that the Gas Control Pilot Sc...

Page 23: ...he pin and re fit it back to the cap the correct way for the gas type to be used Either LP or NAT should be visible on the flank of the pin once re fitted to the cap 4 Screw the cap back into the regulator Gas Type Identification Label On completion of the gas conversion replace the gas type identification label located at the rear of the unit above the gas entry port Low Fire Adjustment The gas c...

Page 24: ...eck the Low Fire burner operation Check the High Fire Burner operation Ensure that all the controls operate correctly Ensure that the operating pressure remains correct 3 Ensure Gas Control Pilot Screw is adjusted to 3 turns Out c c w 4 Ensure any adjustments done to components that have the adjustments settings sealed e g paint sealed are re sealed NOTE If for some reason it is not possible to ge...

Page 25: ... Natural Gas G20 Propane G31 GP514 GP516 GP518 GP514 GP516 GP518 Main Burner Injector 3 40mm 3 00mm 2 85mm 2 10mm 1 80mm 1 70mm Pilot Burner Injector 0 41 0 25 Low Fire Adjustment 1 Turn Out c c w High Fire Adjustment Maximum Flow Screw Fully In c w Note 1 Operating Pressure 8 5 mbar Note 2 8 2 mbar Note 2 Supply Pressure 20 mbar 37 mbar Gas Regulator Cap Screw 26 mbar Note 2 Natural Gas LP Gas Pr...

Page 26: ...jector Nat 2 85mm GP518 032210 Main Injector LPG 2 10mm GP514 032180 Main Injector LPG 1 80mm GP516 032170 Main Injector LPG 1 70mm GP518 019593 Pilot Injector Nat 0 41mm 019594 Pilot Injector LPG 0 25mm 228531 Regulator RV48CLM Natural Gas LPG convertible BSP female General 228400 Grease Drawer 227850 Leg 150mm Adjustable Flush Stud 229674 Rear Roller Assy 232351 Rear Roller Assy 3 Refrigerator B...

Page 27: ...B Models only 228801 Refrigeration Base 900mm Plinth Kit RB Models only 228805 Refrigeration Base 1200mm Plinth Kit RB Models only Replacement Parts List For the Refrigeration Cabinet Replacement Parts refer to the Refrigeration Cabinet Installation and Operation Manual supplied with the appliance Models Gas Type to Convert to Australia New Zealand Only Nat Gas LPG Nat Gas Propane GP514 232025 232...

Page 28: ...26 ...

Page 29: ...27 ...