4
Specifications
- CE Only:
Appliance Classification
Category:
II
2H3P
(20, 30 / 37).
Flue Type:
A
1.
* The burner operating pressure is to be measured at the manifold test point with two
burners operating at full setting. The operating pressure is ex-factory set, through the
appliance regulator and is not to be adjusted, apart from when carrying out gas
conversion, if required. (Refer to the ‘Gas Conversion’ section for details).
Gas Connection
Gas supply connection point is located at the rear of the appliance, approximately 130 mm from the
right hand side, 35 mm from the rear and 655 mm from the floor and is reached from beneath the
appliance. (Refer to the ‘Dimensions’ section).
Connection is ¾" BSP male thread.
Electrical Supply Requirements
MODEL
1-Phase Connection
1P+N+E
230-240V
GE505
5.5 kW,
22.6 Amps @ 235 V
5.5 kW
L1 - 7.2 Amps
L2 - 7.7 Amps
L3 - 7.7 Amps
GE54
5.8 kW,
23.9 Amps @ 235 V
5.8 kW
L1 - 8.5 Amps
L2 - 7.7 Amps
L3 - 7.7 Amps
GE506
6.5 kW,
26.6 Amps @ 235 V
6.5 kW
L1 - 8.2 Amps
L2 - 9.2 Amps
L3 - 9.2 Amps
GE56
6.8 kW,
27.9 Amps @ 235 V
6.8 kW
L1 - 9.5 Amps
L2 - 9.2 Amps
L3 - 9.2 Amps
GE508
6.5 kW,
26.6 Amps @ 235 V
6.5 kW
L1 - 8.2 Amps
L2 - 9.2 Amps
L3 - 9.2 Amps
GE58
6.8 kW,
27.9 Amps @ 235 V
6.8 kW
L1 - 9.5 Amps
L2 - 9.2 Amps
L3 - 9.2 Amps
3-Phase Connection
3P+N+E
400-415V
Natural Gas (G20)
Propane (G31)
Open Burner
(each)
Griddle
(each 300mm section)
Open Burner
(each)
Griddle
(each 300mm section)
Heat Input
(nett)
Nominal
6.5 kW
5.5 kW
6.5 kW
5.5 kW
Reduced
1.75 kW
1.85 kW
1.75 kW
1.95 kW
Gas Rate (nett)
Nominal
0.69 m
3
/hr
0.58 m
3
/hr
0.51 kg/hr
0.43 kg/hr
Reduced
0.19 m
3
/hr
0.20 m
3
/hr
0.14 kg/hr
0.15 kg/hr
Supply Pressure
20 mbar
30 / 37 mbar
Burner Operating Pressure
9.5 mbar (*)
26 mbar (*)
Gas Connection
See ‘Gas Connection’ information overleaf
Summary of Contents for Evolution GE505
Page 8: ...6 Dimensions Dimensions GE505 GE54 Refer to Page 8 for Cook Top Options Dimensions GE506 GE56 ...
Page 9: ...7 Dimensions Dimensions GE508 GE58 Refer to Page 8 for Cook Top Options ...
Page 25: ...23 Wiring Schematic Static Ovens GE505 GE506 GE508 Series ...
Page 26: ...24 Wiring Schematic Convection Ovens GE54 GE56 GE58 Series ...
Page 27: ...25 Wiring Schematics Wiring Layout for Static Oven Wiring Layout for Convection Oven ...
Page 36: ...34 ...
Page 37: ...35 ...