12
5.
Connect neutral and earth conductors to neutral stud and earth stud respectively.
6.
For all connections ensure that conductors are secure and appropriately terminated.
7.
Tighten the cable gland to secure against tension on the cable.
8.
Check that the polarity of each connection is correct to the mains connection terminals markings on
the appliance.
NOTE:
•
This appliance must be earthed.
•
Fixed wiring installations must incorporate an all-pole disconnection switch.
9.
Correctly locate the appliance into its final operating position and using a spirit level, adjust the legs
so that the appliance is level and at the correct height.
10. Connect the power supply to the appliance.
11. Check that the electrical supply is within the input rating specification, refer to the “Specifications”
section).
Commissioning
1.
Before leaving the new installation;
a. Check the following functions in accordance with the operating instructions specified in the
“Operation” section of this manual.
•
Light the Griddle.
•
Light the Open Burners. (F - Flame Failure Option).
•
Light the Open Burners. (PF - Pilot and Flame Failure Option).
•
Check the Low Fire Burner Operation.
•
Check the High Fire Burner Operation.
•
Check the Oven Heating.
•
Check the Oven Thermostat Operation.
•
Check the Oven Fan Operation (GEC Models only).
b. Ensure that the operator has been instructed in the areas of correct lighting, operation, and
shutdown procedure for the appliance.
2.
This manual must be kept by the owner for future reference, and a record of the
Date of
Purchase,
Date of Installation
and
Serial Number of the Appliance
recorded and kept with
this manual.
(These details can be found on the Rating Plate attached to the front right
hand corner of the bottom sill. Refer to the ‘Gas Connection’ section)
.
NOTE: If for some reason it is not possible to get the appliance to operate correctly, shut off the
gas supply and contact the supplier of this appliance.
Installation
C
AUTION
:
Changing the supply from 3 phase to single phase will increase the electrical
current loading on the supply cable. Ensure that the supply cable used is of a
sufficient size for the current loading, refer to the 'Electrical Supply
Requirements' table overleaf.
Summary of Contents for Evolution GE505
Page 8: ...6 Dimensions Dimensions GE505 GE54 Refer to Page 8 for Cook Top Options Dimensions GE506 GE56 ...
Page 9: ...7 Dimensions Dimensions GE508 GE58 Refer to Page 8 for Cook Top Options ...
Page 25: ...23 Wiring Schematic Static Ovens GE505 GE506 GE508 Series ...
Page 26: ...24 Wiring Schematic Convection Ovens GE54 GE56 GE58 Series ...
Page 27: ...25 Wiring Schematics Wiring Layout for Static Oven Wiring Layout for Convection Oven ...
Page 36: ...34 ...
Page 37: ...35 ...