Installation Requirements
NOTE:
•
It is most important that this appliance is installed correctly and that operation is correct
before use. Installation shall comply with local electrical, gas, health and safety
requirements.
•
This appliance shall be installed with sufficient ventilation to prevent the occurrence of
unacceptable concentrations of health harmful substances in the room, the appliance is
installed in.
Blue Seal Convection Ovens are designed to provide years of satisfactory service, and correct installation is
essential to achieve the best performance, efficiency and trouble-free operation.
This appliance must be installed in accordance with National installation codes and in addition, in
accordance with relevant National / Local codes covering gas, electrical and fire safety.
Australia:
- AS5601
- Gas Installations.
New
Zealand:
- NZS5261
- Gas Installation.
Australia / New Zealand:
- AS / NZS3000 - Wiring Rules.
United
Kingdom:
- Gas Safety (Installation & Use) Regulations 1998.
- BS6173
- Installation of Catering Appliances.
- BS5440 1 & 2 - Installation Flueing & Ventilation.
- BS7671
- Requirements for Electrical Installation.
Ireland:
- IS 820
- Non - Domestic Gas Installations.
Installations must be carried out by authorised persons only. Failure to install equipment to
the relevant codes and manufacturer’s specifications shown in this section will void the
warranty.
Components having adjustments protected (e.g. paint sealed) by the manufacturer are only
allowed to be adjusted by an authorised service agent. They are not to be adjusted by the
installation person.
Unpacking
•
Remove all packaging and transit protection from the appliance including all protective plastic
coating from the exterior stainless steel panels.
•
Check equipment and parts for damage. Report any damage immediately to the carrier and
distributor.
•
Report any deficiencies to the distributor who supplied the appliance.
•
Check that the available gas and electrical supply is correct to that shown on the rating plate located
on the front right hand corner of the bottom sill.
Location
1.
Installation must allow for a sufficient flow of fresh air for the combustion air supply.
2.
Installation must include adequate ventilation means, to prevent dangerous build up of combustion
products.
3.
Never directly connect a ventilation system to the appliance flue outlet.
4.
Position the appliance in its approximate working position.
5.
All air for burner combustion is supplied from underneath the appliance. The legs must always be
fitted and no obstructions placed on the underside or around the base of the appliance, as
obstructions will cause incorrect operation and/or failure of the appliance.
NOTE: Do not obstruct or block the appliances flue. Never directly connect a ventilation system to
the appliance flue outlet.
Installation
Combustion Air Requirements:
GE505 / GE54
GE506 / GE56
GE508 / GE58
Natural Gas (G20)
24 m
3
/hr 36
m
3
/hr 48
m
3
/hr
LPG (G31)
25 m
3
/hr 38
m
3
/hr 50
m
3
/hr
Summary of Contents for Evolution GE505
Page 8: ...6 Dimensions Dimensions GE505 GE54 Refer to Page 8 for Cook Top Options Dimensions GE506 GE56 ...
Page 9: ...7 Dimensions Dimensions GE508 GE58 Refer to Page 8 for Cook Top Options ...
Page 25: ...23 Wiring Schematic Static Ovens GE505 GE506 GE508 Series ...
Page 26: ...24 Wiring Schematic Convection Ovens GE54 GE56 GE58 Series ...
Page 27: ...25 Wiring Schematics Wiring Layout for Static Oven Wiring Layout for Convection Oven ...
Page 36: ...34 ...
Page 37: ...35 ...