4.1. Keypad Function

Button

Symbol

Function Description

Set/Enter

Confirm

s

your choice

Exit/Esc 

Exit

s

to previous mode/setting

Up 

Increase

s

volume/  change

s

parameter

Down 

Decrease

s

volume/  change

s

parameter

Reset

Piston  automatically  determines 
the home position

Start

START

Activate

s

aspirating/dispensing

/

Replace

button

Tip 

Ejector

TIP

Eject

s

the tips

Tips On Efficient Operation:

START

button can be used to increase 

volumes, and to change modes and settings as “Up” button during 
the volume settings and function mode selection. This unique design 
will speed up the setting processes.

RESET

10

Summary of Contents for BluePette

Page 1: ...BluePette Single and Multichannel Electronic Pipettes User Manual Version 1 0 Copyright 2018 Blue Ray Biotech Corp All Rights Reserved...

Page 2: ......

Page 3: ...ery 5 3 3 Charging the Battery 5 3 4 Start Pipetting 7 3 5 Hanger Installation 8 4 Overview 8 4 1 Keypad Function 10 4 2 Acoustic Signals 11 5 Function Map 12 6 SYS System Mode 13 6 1 Aspirating Speed...

Page 4: ...19 10 2 SD Sequential Dispensing Mode 21 11 Sterilization 22 11 1 Disassemble Lower Part 23 11 2 Reassemble Lower Part 24 12 Maintenance 25 13 Troubleshooting 25 Appendix A Technical Specifications 28...

Page 5: ...potentially explosive environment or with potentially explosive chemicals 2 When using organic solvents or corrosive chemicals please ensure that they are compatible with the pipette tips and the pip...

Page 6: ...ed original charger unit to charge the battery 9 Do not use a leaking battery 10 If charging is not completed within the specified time period unplug the charger and discontinue charging immediately 1...

Page 7: ...h accuracy and precision Force savings Useful practical operation protocols such as Automatic Pipetting AUTO Multiple Dispensing MD Mixing MIX and Sequential Aspirating Dispensing SE etc Storage of up...

Page 8: ...nger and accessories Pipette tips 1 battery charger set and 1 extra battery If there are any items missing damaged or not according to your order please contact your distributor or sales representativ...

Page 9: ...ote After the battery is inserted the pipette will automatically carry out a calibration routine 3 3 Charging the Battery Internal Charging Circuit Insert the battery into the battery compartment Inse...

Page 10: ...ing will stop and the pipette will beep once to remind the user Figure 3 Using the internal charging circuit to charge the battery Note 1 For safety concerns the pipette shall not be used during the c...

Page 11: ...witched off if it s not in use for more than 10 minutes Select the desired function mode and settings refer to the following chapters 6 10 before pipetting After the initial set up please attach the c...

Page 12: ...de accessory bag as shown in Figure 5 The finger rest can be attached to the hanger to keep the pipette in a vertical position Figure 5 Hanger installation 4 Overview This section presents an overview...

Page 13: ...r Alarm Blow Out Reverse Pipetting Front View Side View LCD Display Keypad Bushing Lower Part Tip Fitting Tip Ejector Battery Cover Start Button Reset Button Connecting Nut Start Button EXIST Button B...

Page 14: ...parameter Reset Piston automatically determines the home position Start START Activates aspirating dispensing Replace button Tip Ejector TIP Ejects the tips Tips On Efficient Operation START button ca...

Page 15: ...zing yourself with the operating procedure of the BluePette They can also be switched off if required see Section 6 3 Acoustic Sound Operation Low tone beep Aspirating High tone beep Dispensing Tip Ej...

Page 16: ...e Figure 8 Figure 8 Function map Function Map AUTO Functio n Mode Aspirating Speed Dispensing Number COUNT Mix Number COUNT Dispensing Speed Acoustic Signals Program Recall Reverse Pipetting Tip Eject...

Page 17: ...in memory you have to complete the whole setting procedure and press SET when the LCD displays 2 You can use the Up Down button to move back and forth to the previous function settings 6 1 Aspirating...

Page 18: ...Press Up Down to select the preference On Off 3 Press SET to confirm the selection and move to the Tip Ejection Alarm setting 6 4 Tip Ejector Alarm The tip ejector alarm is designed to remind the use...

Page 19: ...t is important to withdraw the tip quickly from the dispensing sample vessel after dispense if Blow out is selected because the piston will retract a short distance for creating the blow out volume 6...

Page 20: ...Storage Locations 1 Complete the setup of function mode e g AUTO MD MIX mode 2 Press and hold Down for 3 seconds to enter PROG mode 3 Press Up Down to select PROG number from 01 09 4 Press SET to con...

Page 21: ...selection 3 Use Up Down to select the desired pipetting volume 4 Press SET to confirm selected volume and readiness for pipetting Tip You may use the START button to replace Up to speed up the volume...

Page 22: ...pipetting count The pipetting volume will show the total aspirating volume 8 After the settings are completed first press the START button to aspirate the sample according to the pipetting volume Nex...

Page 23: ...n After the completion of mixing pressing the START button will re activate the mixing process until the user changes the function mode 10 SE Sequential Aspirating Dispensing Mode SE mode includes SA...

Page 24: ...hat the pipette is ready for liquid pick up Press the START button to aspirate the samples will appear to remind users to create an air gap between sample aspirations 11 When the aspirations are compl...

Page 25: ...lashing 5 Press SET to confirm the selection 6 Under symbol 01 will appear Press Up Down to set the volume of the first dispensing 7 Press SET to confirm the selection 8 Repeat steps 6 and 7 to set th...

Page 26: ...t of the pipette can be steam autoclaved 121 o C 1 bar 20 minutes The autoclaved parts must be allowed to dry completely at room temperature for at least 2 hours You can follow Figures 10 13 to disass...

Page 27: ...as shown in Figure 10 3 Pull the lower part downward slowly until the cylinder lock appears as shown in Figure 11 4 Please place the pipette on a flat surface Push the cylinder lock downwards until yo...

Page 28: ...part of the pipette 1 Press the START button or any button of the keypad to make the step motor shaft retract inside of upper part for 1 cm The step motor will automatically retract inside of upper l...

Page 29: ...ubricate the pipette more frequently Only trained representatives or users are recommended to lubricate the piston Please use the lubricant as offered by the supplier only It is recommended to check t...

Page 30: ...d service provider for repair Symptom Possible Cause Solution Err 01 Bad battery Charge the battery Bad power adaptor Replace the power adaptor Err 02 Auto calibration is not working Press the button...

Page 31: ...sh away the foreign objects Piston blocks Lubricate piston Power on failure Bad battery contact Reinsert the battery Rusted battery contact Replace with new battery Dead battery Charge the battery Fun...

Page 32: ...tor Power Saving Yes after 10 minutes Power Adaptor 100 120 220 240 V AC DC 3 6 V Acoustic Indication Yes Autoclavable Yes for lower part only Operating Temperature 5 50 o C Operating Humidity RH 0 85...

Page 33: ...lat head screwdriver or other tool to rotate the tip ejector height adjustment nut By rotating the nut in counter clockwise direction the tip ejector will move closer to the mouth of tip fitting This...

Page 34: ...caused by excessive tear and wear or damage due to shipping accident abuse misuse problems with electrical power or usage not in accordance with product instructions or if other than original spare p...

Page 35: ...duct Name BluePette Single 8 channel Electronic Pipettes Model Names B20 1 B200 1 B1000 1 B20 8 B200 8 All models comply with the following European standards EMC EN55011 Class A Safety EN61010 1 1 2...

Page 36: ......

Page 37: ......

Page 38: ......

Page 39: ......

Page 40: ...www blue raybio com 4F NO 31 Sec 2 Chang an E Rd ZhongShan Dist Taipei City 10456 Taiwan R O C P N 401 apbr00 10...