About This Guide
ProxySG 900 Series Maintenance & Upgrade Guide
23
Upgrading from the SG900-30 to a SG900-45
Follow the listed steps to upgrade the SG900-30 to a SG900-45.
Upgrade
Steps
Description
1
Power down the appliance. See the
ProxySG 900 Series Quick Start Guide
for additional information.
2
Add additional HDDs.
See, “Hard Disk Drive” on page 35.
3
Replace existing memory modules.
See, “Memory Module” on page 47.
4
Replace the existing CPU and heatsink unit.
See, “Processor (CPU)” on page 57.
5
Power on the appliance. See the
ProxySG 900 Series Quick Start Guide
for additional information.
6
Install new license keys.
See ‘Chapter 3: Licensing’ of the SGOS Admininstration Guide for additional instructions.