SERVICING INSTRUCTIONS (continued) 

14 

PROCEDURE:  Delime the Water Tank  

 
PRECAUTIONS:     Disconnect dispenser from electric power.  
                                Allow dispenser to cool. 

 
FREQUENCY:        As required (Dispenser slow to heat) 

 
TOOLS:                  Deliming Solution 
                                Protective Gloves, Goggles & Apron 
                                Mild Detergent, Clean Soft Cloth or Sponge 
                                Bristle Brush, Bottle Brush 
                                Large Sink (or other appropriate work area) 

 

1.    Disconnect dispenser from electric power.   Disconnect the
       water supply line from the inlet fitting. 

 
2.    Remove the tank lid assembly as described on page 12. 

 
3.

Remove two screws holding tank to dispenser cabinet.      
Remove the water tank from the dispenser body by lifting 
straight up.  Disconnect chassis ground lead from tank.  
Empty all water from the tank.  Set the tank back into the unit. 

 
4.    Mix 2 quarts of deliming solution according to the            
       manufacturer’s directions.  Carefully pour the deliming 
       solution into the water tank.  Lower the lid assembly back      
       onto the tank.  Allow to sit for 30 minutes, or as directed by 
       the  manufacturer. 

 
5.    At end of soaking period, remove lid assembly from tank.  
       Thoroughly rinse internal components of lid assembly with 
       clear water.  Using a stiff bristle brush, scrub the heating    
       element to remove lime and calcium build-up.  Rinse with 
       clean water.  Store lid assembly in a safe location. 

 
6.    Remove the tank from the dispenser and empty.  Using a stiff 
       bristle brush, scrub the interior of the water  tank to remove 
       lime and calcium build-up.  Rinse with clean water. 

 
7.    Reconnect the chassis ground lead and set the tank back into 
       the dispenser.  Install the two mounting screws.  Reassemble 
       the tank lid to the water tank.  Make sure the gasket is     
       properly in place, then reinstall the hold-down strap. 

 
8.    Reinstall wiring to heating element and thermostat.  Reinstall 
       the hi-limit thermostat (if removed).  Verify that all internal    
       components are dry, then reinstall the top panel. 

 
10. Reconnect dispenser to electrical supply and reconnect water 

supply. 

 
11.  Place an empty container under the dispense nozzle. 
       Dispense at least 10 full cups of water and discard all water    
       generated. 

 
12.  Dispenser is ready to use. 

CAUTION:  

CHEMICAL BURN 
HAZARD

 

Deliming chemicals may be 
caustic.  Wear appropriate     
protective gloves and goggles 
during this procedure. 
Never siphon deliming      
chemicals or solutions by 
mouth. 
This operation should only be 
performed by qualified and    
experienced service personnel. 
 
 

IMPORTANT: 

 

DO NOT 

spill, 

splash or pour water or deliming 
solution into or over any internal 
component other than the inside 
of the water tank. 
 
 

IMPORTANT: 

 

DO NOT 

allow 

any internal components to 
come into contact with the     
deliming solution.  Take care to 
keep all internal components 
dry. 
 
 

NOTE:

  Repeat steps 4 thru 5 

as required to remove all scale 
and lime build-up. 
 
 

NOTE: 

 Normally, silicone 

hoses do not need to be        
delimed.  Should deliming 
hoses become necessary, 
Bloomfield recommends        
replacing the hoses. 

714

5  
 7738

0

  Ow

ners

 M
a

nual H

o

ri

z

on™ 040

H

o

W
a

ter
 D
is

p

enser

 

Summary of Contents for Horizon 0401

Page 1: ...NTED IN CHINA 714 p n 77380 Rev ECN 12917 M714 050913 cps Model 0401 OWNERS MANUAL For HOT WATER DISPENSER MODELS 0401 Hot Water Dispenser Includes Installation Operation Use Care Servicing Instructio...

Page 2: ...90 days parts warranty only excludes decanters THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FI...

Page 3: ...ns the information needed to properly install this appliance and to use care for and maintain or repair the appliance in a manner which will ensure its optimum performance WARRANTY STATEMENT xi SPECIF...

Page 4: ...FEATURES AND OPERATING CONTROLS HOT WATER DISPENSER 2 Fig 1 Features Operating Controls 685 77110 Owners Manual Horizon Brewers...

Page 5: ...calding can occur from contact with dispensed liquids This appliance is intended for commercial use only This appliance is intended for use to dispense hot water for human consumption No other use is...

Page 6: ...ts should be done before the actual unit installation is started CAUTION ELECTRICAL DAMAGE DO NOT plug in or energize this appliance until all Installation Instructions are read and followed Damage to...

Page 7: ...s requirement See Figure 2 below In some areas local codes require a backflow preventer check valve to be installed on the inlet water line If a backflow preventer is used you must install a water ham...

Page 8: ...such a ground Electrical shock will cause death or serious injury IMPORTANT Supply power must match nameplate for voltage and phase Connecting to the wrong voltage will damage the Dispenser or result...

Page 9: ...WITCH ON When READY light glows unit is ready for use 5 Be sure the DRIP TRAY is empty and the CUP GRID is properly installed Locate the cup grid and drip tray in place under the dispense nozzle B USI...

Page 10: ...en the dispenser cools WATER LEVEL Water level is controlled by an electronic controller The water level probe senses chassis ground through the water When the water level is below the probe no ground...

Page 11: ...ozzle to remove any mineral deposits A bristle brush may be used to remove stubborn mineral build up 4 Empty drip tray Drip tray and cup grid may be washed in the sink with warm water and mild deterge...

Page 12: ...Water supply OFF Turn water supply ON Inlet solenoid strainer plugged Clean strainer Dispense solenoid damaged Replace dispense solenoid Water level probe grounded Check repair wiring to probe Check...

Page 13: ...urning shaft clockwise increases temperature 1 8 turn approximately 10 F Refer to Table 1 below for proper brewing temperature based on altitude Upon completion remove thermometer and reinstall the ve...

Page 14: ...Remove hold down bracket by sliding short slotted end off of locking stud and lifting it off Remove cover assembly by lifting it straight up Reassemble in reverse order REPLACE THERMOSTAT Disconnect d...

Page 15: ...lectric power Turn OFF water supply Remove top panel Remove mounting screw from terminal block and position terminal block out of the way Disconnect wiring from dispense solenoid Slide hoses from sole...

Page 16: ...e interior of the water tank to remove lime and calcium build up Rinse with clean water 7 Reconnect the chassis ground lead and set the tank back into the dispenser Install the two mounting screws Rea...

Page 17: ...WIRING DIAGRAM 15 7145 77380 Owners Manual Horizon 0401 Hot Water Dispenser...

Page 18: ...EXPLODED VIEW PARTS LIST 16 PLUMBING RELATED COMPONENTS MODELS 0401 7145 77380 Owners Manual Horizon 0401 Hot Water Dispenser...

Page 19: ...EXPLODED VIEW PARTS LIST continued 17 CABINET CHASSIS ELECTRICAL COMPONENTS MODEL 0401 7145 77380 Owners Manual Horizon 0401 Hot Water Dispenser...

Page 20: ...n of Carrier Commercial Refrigeration In US and Canada Telephone 775 689 5700 Fax 888 492 2783 Fax 800 356 5142 website www wellsbloomfield com for orders only Bloomfield Industries proudly supports C...

Reviews: