71
45
7738
0
Ow
ners
M
anual H
o
ri
z
on™ 040
1
H
o
t
W
a
te
r D
is
p
enser
SERVICING INSTRUCTIONS
TEMPERATURE ADJUSTMENT
Disconnect dispenser from electric power. Remove top panel.
Pull vent tube out of tank lid and insert a thermometer of known
accuracy in hole. Reconnect dispenser to electrical power.
Place empty container under dispense nozzle.
Energize dispenser and allow unit to heat. When READY light
glows, read the temperature displayed on thermometer.
Adjust thermostat by turning shaft; clockwise increases
temperature. 1/8 turn = approximately 10ºF.
Refer to Table 1 below for proper brewing temperature based on
altitude.
Upon completion, remove thermometer and reinstall the vent
tube.
Fig. 5 Checking and Adjusting Water Temperature
CAUTION:
SHOCK HAZARD
These procedures involve
exposed electrical circuits.
These procedures are to be
performed by qualified
technical personnel only.
IMPORTANT:
A mechanical thermostat will
maintain temperature within
±5ºF. To prevent boiling water
in the brewer, thermostat should
be adjusted to a maximum
temperature equal to the local
boiling temperature minus 5ºF.
Table 1 Boiling Temperature by Altitude
11