background image

MODEL 

STYLE 

FEATURES 

VOLTS 

WATTS 

AMPS 

1ø 

POWER SUPPLY 

CORD 

9600  

SINGLE 

CUP 

COFFEE 

BREWER 

HOT 

WATER 

DISPENSER  

120 VAC  

1500 

NEMA 5-15P  

12.5 

TABLE OF CONTENTS 

SPECIFICATIONS 

Thank You for purchasing this 
Bloomfield Industries appliance. 
 
Proper installation, professional 
operation and consistent 
maintenance of this appliance will 
ensure that it gives you the very 
best  performance  and  a  long, 
economical service life.  
 
This manual contains the 
information needed to properly 
install this appliance, and to use, 
care for and maintain or repair the 
appliance in a manner which will 
ensure its optimum performance. 

WARRANTY STATEMENT                                  xi 
SPECIFICATIONS                                                  1 
FEATURES & OPERATING CONTROLS            2   
PRECAUTIONS & GENERAL INFORMATION    3 
AGENCY LISTING INFORMATION                      3 
INSTALLATION INSTRUCTIONS                         4 
OPERATION                                                            7 
           Program Volume Select Keys                    8 
           Brew Coffee                                                  9 
CLEANING INSTRUCTIONS                              10   
TROUBLESHOOTING SUGGESTIONS             11 
SERVICING INSTRUCTIONS                            12 
           Deliming Instructions                                17 
EXPLODED VIEW & PARTS LIST                     18 
WIRING DIAGRAMS                                            21 

APPLICABILITY 

This manual applies to the following Bloomfield Industries product: 
9600, 9600CA 

Summary of Contents for 9600 Single Cup

Page 1: ...TED IN CHINA 687 p n 77195 Rev ECN12792 M687 050207 cps Model 9600 Single Cup Brewer OWNERS MANUAL For COFFEE BREWERS MODELS 9600 SINGLE CUP INCLUDES Installation Operation Use Care Servicing Instruct...

Page 2: ...ffee carry a 90 days parts warranty only excludes decanters THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTA...

Page 3: ...s the information needed to properly install this appliance and to use care for and maintain or repair the appliance in a manner which will ensure its optimum performance WARRANTY STATEMENT xi SPECIFI...

Page 4: ...FEATURES AND OPERATING CONTROLS AUTOMATIC BREWERS 2 Fig 1 Features Operating Controls for Single Cup Brewers...

Page 5: ...oducts for human consumption No other use is recommended or authorized by the manufacturer or its agents This appliance is intended for use in commercial establishments where all operators are familia...

Page 6: ...the counter to prevent tipping IMPORTANT To enable the installer to make a quality installation and to minimize installation time the following suggestions and tests should be done before the actual u...

Page 7: ...that must use a saddle tap shut off the main water supply and drill a 3 16 minimum tap for the saddle connection in order to insure an ample water supply Remember to flush the line prior to installin...

Page 8: ...d to protect you from electrical shock in the event of internal damage Never cut off the ground prong nor twist a blade to fit an existing receptacle Contact a licensed electrician to install the prop...

Page 9: ...illing When solenoid closes tank is full 2 Place an empty container on the cup grid Press the HOT WATER DISPENSE BUTTON and dispense one cup of water Tank should refill Discard water 3 Press TANK HEAT...

Page 10: ...beep sounds to enter the setting into memory OR For PULSE BREW a Press and release the key to start the water flow b Press and release the key again to stop the flow after the time desired for the fir...

Page 11: ...od holder by pulling the LOCKING LEVER fully forward 2 Pull the BREW TRAY fully forward This will automatically eject the used pod 3 Slide the tray fully to the rear In order to prevent an unintended...

Page 12: ...cloth moistened with clean water 6 Wash the pod drawer drip tray and cup grid in a sink using warm water and a mild detergent Rinse with clean water and allow to air dry 7 Wipe the exterior of the bre...

Page 13: ...OCKING LEVER fully forward 9 Pull the BREW TRAY fully forward to eject the sanitizer packet then slide it fully to the rear Gently pull the LOCKING LEVER DOWN then push it fully to the rear to lock th...

Page 14: ...Solenoid inlet strainer plugged Clean strainer Water filter if used plugged Replace filter element Damaged internal component or wiring Check wiring connectors inlet solenoid controller and water lev...

Page 15: ...NEL Remove top panel to access hot water tank thermostat heating elements brew pump and tubing brew solenoid hot water dispenser solenoid and piping pod holders and brew tray Top panel is held by scre...

Page 16: ...e to be performed by qualified technical personnel only NOTE Optimum brewing temperature range is 195 F to 205 F 90 C to 96 C IMPORTANT A mechanical thermostat will maintain temperature within 5 F To...

Page 17: ...t all wiring from heating element Remove tank ground wire Loosen nuts and center screw on tank hold down strap Remove hold down strap by sliding short slotted end off of locking stud and lifting it of...

Page 18: ...om turning while installing or removing the inlet water supply flare nut Remove fill tubing Disconnect wiring Remove two screws holding solenoid to access door Reassemble in reverse order CLEAN SOLENO...

Page 19: ...retaining screw and elbow fitting Be sure elbow fitting o ring and ring plate o ring are properly reinstalled after cleaning Clean all components using mild detergent and clean water Rinse with clean...

Page 20: ...orientation REPLACE CONTROLLER Disconnect brewer from electric power Remove top panel Note location of wire connections Be sure to mark the two keypad ribbon cables as to orientation Disconnect wirin...

Page 21: ...id assembly as described on page 15 3 Remove the water tank from the brewer body by lifting straight up Empty all water from the tank Set the tank back into the brewer 4 Mix 2 quarts of deliming solut...

Page 22: ...EXPLODED VIEW PARTS LIST 20 CABINET COMPONENTS...

Page 23: ...VENT TUBE LONG 1 20 8043 83 HI LIMIT THERMOSTAT 1 21 87172 TUBE FILL 1 22 83521 PROBE WATER LEVEL 1 23 82390 GROMMET 3 8 1 24 83532 SLEEVE PROBE 1 ITEM PART NO DESCRIPTION QTY 25 86968 TANK COVER 1 2...

Page 24: ...EXPLODED VIEW PARTS LIST 22 BREW TRAY COMPONENTS...

Page 25: ...SWING ARM LEFT 1 70 86851 SWING ARM RIGHT 1 71 86980 COTTER PIN 06Dx 5 SS 2 72 86977 PIVOT ROD 1 73 86974 BEARING THRUST 2 74 SPRING 1 75 86970 O RING 2 039 1 ITEM PART NO DESCRIPTION QTY 76 86846 RI...

Page 26: ...EXPLODED VIEW PARTS LIST continued 24 SERVICE PARTS KITS 84427 VALVE ASSEMBLY COMPLETE 85218 INLET FITTING KIT Includes cap fitting gasket strainer 85219 INLET STRAINER...

Page 27: ...25 WIRING DIAGRAM...

Page 28: ...n of Carrier Commercial Refrigeration In US and Canada Telephone 775 689 5700 Fax 888 492 2783 Fax 800 356 5142 website www wellsbloomfield com for orders only Bloomfield Industries proudly supports C...

Reviews: