OPERATION - BREWING COFFEE 

1.

   

Unlock the pod holder by pulling the LOCKING LEVER fully        

       forward. 

 
2.    Pull the BREW TRAY fully forward, then lower tray. 

 
      

NOTE:  

Normally, the brewer will automatically discard the last pod.  

       If the brewer has not been used for some time, the used pod may 
       need to be removed by hand.  Deposit the used pod in the pod bin. 

 
3.

Center a fresh pod on the grid of the LOWER POD HOLDER. 

 
 
 
 
 
 
 
 
 
 
4.    Raise the BREW TRAY and slide fully to the rear. 

 
5.    Gently pull the LOCKING LEVER 

DOWN

, then push it fully to the rear 

       to lock the pod holder. 

 
6.

Place an 

EMPTY

 cup on the CUP GRID, under the BREW NOZZLE. 

 
7.    When the READY light glows, press the appropriate BREW KEY.  
       Fresh coffee (or tea) will begin to fill the cup. 
       Three beeps will sound.  When all dripping stops, beverage is ready 
       to serve. 

 
 

SUGGESTION:  

If the brewer is likely to remain unused for some time, 

discard the used pod: 

 
1.    Unlatch the pod holder by pulling the LOCKING LEVER fully        
       forward. 

 
2.

Pull the BREW TRAY fully forward.  This will automatically eject the 
used pod.  

 
3.    Slide the tray fully to the rear.  In order to prevent an unintended 
       brew, do not lock the pod holder. 

CAUTION:   

BURN HAZARD  

 

Exposed surfaces of the 
brewer may be HOT to the 
touch, and can cause    
serious burns. 

 

CAUTION:  

BURN HAZARD 

 

To avoid splashing or   
overflowing hot liquids, 
ALWAYS place an EMPTY 
cup on the cup grid before 
starting the brew cycle.  
Failure to comply can 
cause serious burns.  

 

CAUTION: 

BURN HAZARD 

 

After a brew cycle, pod 
holder and used pod may 
be HOT.  Remove and  
dispose of used pods with 
care.  Failure to comply 
can cause serious burns.  
 

NOTE:  

Press the same 

BREW SELECT KEY at 
any time  during the brew 
to CANCEL. 
 
FOR HOT WATER: 
Place an empty cup on    
the CUP GRID under the 
FAUCET NOZZLE. 
Press the HOT WATER 
DISPENSE button.        
Release the button to stop 
the flow. 

NOTE: 

Hot water dispense is     
disabled during  brew     
cycle. 
 
If the EMPTY DRAW light 
is lit, the used pod bin is 
full.  Remove the drip tray 
assembly, then withdraw 
and empty the POD 
DRAWER. 

Summary of Contents for 9600 Single Cup

Page 1: ...TED IN CHINA 687 p n 77195 Rev ECN12792 M687 050207 cps Model 9600 Single Cup Brewer OWNERS MANUAL For COFFEE BREWERS MODELS 9600 SINGLE CUP INCLUDES Installation Operation Use Care Servicing Instruct...

Page 2: ...ffee carry a 90 days parts warranty only excludes decanters THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTA...

Page 3: ...s the information needed to properly install this appliance and to use care for and maintain or repair the appliance in a manner which will ensure its optimum performance WARRANTY STATEMENT xi SPECIFI...

Page 4: ...FEATURES AND OPERATING CONTROLS AUTOMATIC BREWERS 2 Fig 1 Features Operating Controls for Single Cup Brewers...

Page 5: ...oducts for human consumption No other use is recommended or authorized by the manufacturer or its agents This appliance is intended for use in commercial establishments where all operators are familia...

Page 6: ...the counter to prevent tipping IMPORTANT To enable the installer to make a quality installation and to minimize installation time the following suggestions and tests should be done before the actual u...

Page 7: ...that must use a saddle tap shut off the main water supply and drill a 3 16 minimum tap for the saddle connection in order to insure an ample water supply Remember to flush the line prior to installin...

Page 8: ...d to protect you from electrical shock in the event of internal damage Never cut off the ground prong nor twist a blade to fit an existing receptacle Contact a licensed electrician to install the prop...

Page 9: ...illing When solenoid closes tank is full 2 Place an empty container on the cup grid Press the HOT WATER DISPENSE BUTTON and dispense one cup of water Tank should refill Discard water 3 Press TANK HEAT...

Page 10: ...beep sounds to enter the setting into memory OR For PULSE BREW a Press and release the key to start the water flow b Press and release the key again to stop the flow after the time desired for the fir...

Page 11: ...od holder by pulling the LOCKING LEVER fully forward 2 Pull the BREW TRAY fully forward This will automatically eject the used pod 3 Slide the tray fully to the rear In order to prevent an unintended...

Page 12: ...cloth moistened with clean water 6 Wash the pod drawer drip tray and cup grid in a sink using warm water and a mild detergent Rinse with clean water and allow to air dry 7 Wipe the exterior of the bre...

Page 13: ...OCKING LEVER fully forward 9 Pull the BREW TRAY fully forward to eject the sanitizer packet then slide it fully to the rear Gently pull the LOCKING LEVER DOWN then push it fully to the rear to lock th...

Page 14: ...Solenoid inlet strainer plugged Clean strainer Water filter if used plugged Replace filter element Damaged internal component or wiring Check wiring connectors inlet solenoid controller and water lev...

Page 15: ...NEL Remove top panel to access hot water tank thermostat heating elements brew pump and tubing brew solenoid hot water dispenser solenoid and piping pod holders and brew tray Top panel is held by scre...

Page 16: ...e to be performed by qualified technical personnel only NOTE Optimum brewing temperature range is 195 F to 205 F 90 C to 96 C IMPORTANT A mechanical thermostat will maintain temperature within 5 F To...

Page 17: ...t all wiring from heating element Remove tank ground wire Loosen nuts and center screw on tank hold down strap Remove hold down strap by sliding short slotted end off of locking stud and lifting it of...

Page 18: ...om turning while installing or removing the inlet water supply flare nut Remove fill tubing Disconnect wiring Remove two screws holding solenoid to access door Reassemble in reverse order CLEAN SOLENO...

Page 19: ...retaining screw and elbow fitting Be sure elbow fitting o ring and ring plate o ring are properly reinstalled after cleaning Clean all components using mild detergent and clean water Rinse with clean...

Page 20: ...orientation REPLACE CONTROLLER Disconnect brewer from electric power Remove top panel Note location of wire connections Be sure to mark the two keypad ribbon cables as to orientation Disconnect wirin...

Page 21: ...id assembly as described on page 15 3 Remove the water tank from the brewer body by lifting straight up Empty all water from the tank Set the tank back into the brewer 4 Mix 2 quarts of deliming solut...

Page 22: ...EXPLODED VIEW PARTS LIST 20 CABINET COMPONENTS...

Page 23: ...VENT TUBE LONG 1 20 8043 83 HI LIMIT THERMOSTAT 1 21 87172 TUBE FILL 1 22 83521 PROBE WATER LEVEL 1 23 82390 GROMMET 3 8 1 24 83532 SLEEVE PROBE 1 ITEM PART NO DESCRIPTION QTY 25 86968 TANK COVER 1 2...

Page 24: ...EXPLODED VIEW PARTS LIST 22 BREW TRAY COMPONENTS...

Page 25: ...SWING ARM LEFT 1 70 86851 SWING ARM RIGHT 1 71 86980 COTTER PIN 06Dx 5 SS 2 72 86977 PIVOT ROD 1 73 86974 BEARING THRUST 2 74 SPRING 1 75 86970 O RING 2 039 1 ITEM PART NO DESCRIPTION QTY 76 86846 RI...

Page 26: ...EXPLODED VIEW PARTS LIST continued 24 SERVICE PARTS KITS 84427 VALVE ASSEMBLY COMPLETE 85218 INLET FITTING KIT Includes cap fitting gasket strainer 85219 INLET STRAINER...

Page 27: ...25 WIRING DIAGRAM...

Page 28: ...n of Carrier Commercial Refrigeration In US and Canada Telephone 775 689 5700 Fax 888 492 2783 Fax 800 356 5142 website www wellsbloomfield com for orders only Bloomfield Industries proudly supports C...

Reviews: