INSTALLATION (continued)
ELECTRICIAN’S INSTALLATION INSTRUCTIONS
REFER TO ELECTRICAL SPECIFICATIONS - Page 1
Check the nameplate to determine correct electrical service
required for the dispenser to be installed.
IMPORTANT:
Before connecting to electricity, make sure the
dispenser is connected to the water supply.
Model 9461KFT requires a dedicated 120 volt single phase
15 amp circuit connected to a properly grounded NEMA 5-15R
receptacle.
STARTUP
Be sure the HEATER ON/OFF SWITCH (item 13) is OFF, then
connect appliance to electric power. Press the POWER ON/OFF
SWITCH (item 58) to the ON position. POWER ON light will glow.
The tank will begin filling. When the tank is full, press the
HEATER ON/OFF SWITCH and SOLENOID ON/OFF SWITCH
to
ON
. The elements will be energized and the tank will begin
to heat. When the water has reached proper dispensing
temperature, the READY light will glow.
Do not install product canisters yet. Place a container under a
dispense nozzle and flow water until all air is purged from the
valves and lines. Repeat for each of the three nozzles.
Be sure drip pan/drip tray is properly assembled and installed.
INITIAL ADJUSTMENTS
Tank temperature thermostat is factory set at 198ºF. If a lower
temperature is necessary:
Remove cabinet top panel. Thermostat on right controls tank
temperature. To lower temperature setting, turn stem counter-
clockwise.
6
IMPORTANT:
The ground prong of the plug is
part of a system designed to
protect you from electrical shock
in the event of internal damage.
Never cut off the ground prong
nor twist a blade to fit an
existing receptacle. Contact a
licensed electrician to install the
proper circuit and receptacle.
Fig 4. Power Connection
IMPORTANT:
Connecting the unit to the
wrong voltage will damage the
dispenser or result in decreased
performance. Such damage is
not covered by warranty.
IMPORTANT:
Do not connect
dispenser to electrical power
until you are ready to fill the
tank. See instructions at left.
NEMA 5-15R
RECEPTACLE
NEMA 5-15P
PLUG
GROUND
PIN