OPERATION
6
IMPORTANT:
All E-Max T brewers are
tested and set at the factory. If
programming adjustments are
necessary, refer to the
E-Max Programming Manual
(p/n 2M-73674).
To over-ride the Brew Wait
mode, press and hold the
BREW key for 3 seconds when
the brewer is in Brew Wait
mode (i.e. when brew light is
flashing). The brew will proceed
immediately regardless of water
temperature. This feature
should only be used when
testing water volume, otherwise
the brew will proceed with the
water below the precise brew
temperature.
Note: the following safety
features have been incorporated
to prevent multiple unattended
brews:
The brew key is disabled during
a brew cycle. This minimizes
the possibility of double
brewing.
When the “Brew” light is on or
flashing, repeated pressing
of the BREW switch will be
ignored, (there will be a beep
each time it is pressed). A Brew
will only be activated when the
“Brew” light is off.
1. Energizing the Brewer
: When electricity has been connected
to the unit, there will be a momentary flash of the power light.
Turn the brewer on by pressing the POWER
key. The brewer will start to fill the tank. With
the proper water supply the tank should be
filled in about 2½ minutes. Once filled, the
heating element will come on until the proper
tank temperature has been reached, (which
will take about 20 minutes on 120-Volt models
or about 12 minutes on 120/240 Volt models).
2. Brewing (Precise Temperature for Brewing — PTB)
: In
the regular operating mode, the E-Max T maintains the tank
temperature /- 1ºF of the brew
temperature. Normally this will mean that
a brew will be started as soon as the
BREW key is pressed. However, there
may be a slight delay if the BREW key is
pressed immediately after a brew has been
completed (notably on 120 volt models).
If the tank temperature is below the brew
temperature, the brew will be delayed,
going into the “Brew Wait” mode, with the brew light flashing.
As soon as the correct temperature is reached the brew will
commence with the brew light on continuously during the brew.
When the brew begins the main warming station will be turned
on automatically (if it is not already on). During the brew cycle,
if the BREW key is pressed, it will be ignored. Only when the
brew is complete can another brew be started.
3. Brew Cancel:
To cancel a brew in progress, press the
CANCEL KEY: two beeps will sound and the “Brew” light will
go out. Water flowing to the brew chamber
will be stopped immediately, but if there is
already water in the brew chamber, it will take
a few moments before this drips through as
tea.
4. Normal Operation (Non Brewing):
When the unit is not
brewing, the E-Max T maintains the water temperature at the
Precise Temperature for Brewing (PTB). The heating element
will cycle on and off automatically to maintain this temperature.
5. After Hours Mode:
If no brew is detected for a pre-selected
length of time, the brewer will enter the After Hours mode.
Temperature will be allowed to drop to save energy. Pressing
the BREW KEY returns the brewer to normal operation.
655 2M-Z17970 Owners Manual E-Maxl Thermal Brewer
IL2715
IL2716
IL2717
OPERATING INSTRUCTIONS