SERVICING INSTRUCTIONS (continued)
10. Reinstall tank lid assembly into hot water tank. Make sure
the lid gasket is properly in place, then reinstall the
hold-down clamps.
11. Remove spray disks and gaskets. Rinse both brew heads
with clean water. Using a stiff brush, scrub spray disk to
remove any lime or calcium build-up. Reinstall gaskets
and spray disks.
13. Reconnect brewer to electrical supply .
14. Install the brew chamber without filter paper or grounds.
15. Place an empty server under the brew chamber. Run at
least five 1-1/2 gallon brew cycles and discard all water
generated at the end of each cycle.
Repeat for the other side.
16. Rinse server with clean water. Reinstall one empty
satellite under each brew chamber.
Brewer is ready to use.
DRAINING HOT WATER TANK
1. Disconnect brewer from the electrical supply
2. Remove the top panel assembly (4 Screws)
3. Remove the front panel assyembly (4 Screws)
4. Release the drain hose & hose clamp assy from the retaining
clip.
5. Bring the drain hose down out the front panel so its lower
than the tank.
6. Remove the red hose cap.
6. Open the hose clamp and drain into container.
CAUTION:
Tank holds 6 gallons of water and can may contain
HOT WATER,
7. When tank is empty, close the hose clamp and place the red
cap back into position.
8. Place the end of the hose back into its retaining clip.
NOTE:
Normally, silicone
hoses do not need to be
delimed. Should deliming hoses
become necessary, Bloomfield
recommends replacing the
hoses.
IMPORTANT:
DO NOT allow
any internal components to
come into contact with the any
deliming solution. Take care to
keep all internal components
dry.
13