background image

This appliance is intended for use in commercial establishments 

only.
This appliance is intended to brew hot beverage, specifically coffee,  

for human consumption.  No other use is

 

recommended or authorized 

by the manufacturer or its agents.
Operators of this appliance must be familiar with the appliance use, 

limitations and associated restrictions.  Operating instructions must be 

read and understood by all persons using or installing this appliance.
Cleanliness of this appliance is essential to good sanitation.  Read and 

follow all included cleaning instructions and schedules to ensure the 

safety of the food product.
Surfaces of the brewer, brew basket and servers can be hot to the 

touch, and may cause burns on contact.
Disconnect the brewer from electrical power before performing any 

maintenance or servicing.
DO NOT submerge servers in water.
DO NOT splash or pour water over, onto or into any controls, 

control panel or wiring.
Any procedure which requires the use of tools must be performed by a 

qualified technician.
This manual is considered to be a permanent part of the appliance.  

This manual and all supplied instructions, diagrams, schematics, parts 

breakdown illustrations, notices and labels must remain with the

appliance if it is sold or moved to another location.
This appliance is made in the USA.  Unless otherwise noted, this

appliance has American sizes on all hardware.

WARNING:

SHOCK HAZARD

 

All servicing requiring access 

to non-insulated electrical 

components must be          

performed by a factory       

authorized  technician.

DO NOT

 open any access 

panel that requires the use   

of tools.  Failure to follow this 

warning can result in severe 

electrical shock.

CAUTION:  

BURN HAZARD

Surfaces of this brewer can 

be hot and can cause burns 

on contact.

GENERAL INFORMATION AND PRECAUTIONS

4

AGENCY APPROVAL INFORMATION

This single thermal brewing system is         listed under E9253

and         listed under E9253.

This single thermal brewing system meets NSF Standard 4 only when 

installed and maintained per the instructions in this manual.

655   2M-Z17970 Owners Manual E-Maxl Thermal Brewer

Summary of Contents for 2795TF

Page 1: ...orldwide com p n 2M Z17970 Rev A M655 140422 655 OWNERS MANUAL for 2795TF SERIES THERMAL COFFEE BREWER with E Max CONTROL MODEL 2795TF Includes Installation Operation Use Care Servicing Instructions E...

Page 2: ...f thermostats microswitches and replacement of fuses and indicating lights are not covered under warranty 5 All problems due to inadequate water supply such as fluctuating or high or low water pressur...

Page 3: ...he appliance in a manner which will ensure its optimum performance WARRANTY STATEMENT xi SPECIFICATIONS 1 FEATURES OPERATING CONTROLS 2 GENERAL INFORMATION PRECAUTIONS 4 AGENCY APPROVAL INFORMATION 4...

Page 4: ...THERMAL SERVER HOT WATER DRIP TRAY 6th KEY LARGE VOLUME 5th KEY SMALL VOLUME 4th KEY STANDARD VOLUME 1st KEY START BREW LED INDICATORS VIEW SCREEN CONTROL PANEL BREW HEAD BREW CHAMBER REMOVED 2nd KEY...

Page 5: ...ber Also lists voltage and wattage rating of brewer Glows when the tank water is up to temperature Located on lower right rear of brewer Turns main power to brewer ON or OFF Holds coffee grounds durin...

Page 6: ...procedure which requires the use of tools must be performed by a qualified technician This manual is considered to be a permanent part of the appliance This manual and all supplied instructions diagra...

Page 7: ...less and not less than 3 8 copper tubing for installations exceeding 12 Brewer must be connected to a COLD water line NOTE DO NOT use a saddle tap for this water line connection A shut off valve must...

Page 8: ...ng mode the E Max T maintains the tank temperature within 1 F of the brew temperature Normally this will mean that a brew will be started as soon as the BREW key is pressed However there may be a slig...

Page 9: ...your choice of pre measured tea leaves Shake the brew chamber gently to level the tea leaves Slide the brew chamber back into place 2 Place an empty dispenser under the brew chamber 3 If any volume ot...

Page 10: ...n the automatic timed OFF mode the brewer can be started by depressing the ON OFF switch The brewer will remain ON until the automatic programmed off time when it will turn OFF and resume normal autom...

Page 11: ...quently this feature saves energy and extend component life While in the After Hours mode the power light will flash continuously When the BREW switch is pressed the E Max T automatically reverts back...

Page 12: ...mperature set in the program factory set at 208 F or 98 C it will go into the over temperature mode as above with all lights flashing except the LCD will read overheat error and Call for Service To re...

Page 13: ...through the brew basket but is diverted from the grounds by a bypass channel The remainder of the water is discharged through the BREW HEAD and flows over the grounds in the brew basket at a PRESET o...

Page 14: ...A bristle brush may be used to clean around the bypass diverters Rinse with clean water and allow to air dry Be sure bypass diverters are properly installed 8 Wipe exterior of brewer and servers with...

Page 15: ...urfaces with dry cloth 6 Reinstall funnel assembly lids drip tray Install satellites on brewer 7 Rinse servers with an empty brew chamber in place press the BREW key and run 1 full cycle into each ser...

Page 16: ...Do not disconnect the tank assembly at this time 3 Drain all water from the hot water tank see DRAINING HOT WATER TANK procedures 4 Mix 10 gallons of deliming solution according to the manufacturer s...

Page 17: ...eady to use DRAINING HOT WATER TANK 1 Disconnect brewer from the electrical supply 2 Remove the top panel assembly 4 Screws 3 Remove the front panel assyembly 4 Screws 4 Release the drain hose hose cl...

Page 18: ...lid assembly in a safe location 4 Mix de liming solution according to the manufacturer s directions Add the de liming solution to the water tank Set lid assembly back on tank Allow to sit for 30 minu...

Page 19: ...the brewer cools then functions normally 5 Heating element may be encrusted with lime or scale build up DELIME BREWER AS DETAILED ON PAGE 16 2 Overheat Error RESET by holding CANCEL switch for 3 secon...

Page 20: ...y pressing the BREW key Y u will hear a beep and the display will change to Test Switch 2 2 Test 2nd key by pressing the CANCEL key You will hear a beep and the display will change to Test Switch 3 3...

Page 21: ...tput 1 Inlet Output 2 Dump Output 3 Heater Output 4 Bypass Output 5 Future not functional at this time Output 6 Future not functional at this time 3 Each component should turn ON in order with only on...

Page 22: ...TF E Max Thermal Brewer 1 2 3 4 5 8 9 10 30 11 12 13 14 16 17 18 20 24 25 1 27 28 29 26 1 SEE DETAIL A 21 22 23 19 15 6 3 7 EXPLODED VIEW 2795TF CABINET AND EXTERIOR COMPONENTS 18 655 2M Z17970 Owners...

Page 23: ...I 72215 1 GASKET SPRAY HEAD 1 5 ID 13 A6 72727 1 SPRAY HEAD DISC EMBOSSED 14 D7 76652 1 CHAMBER BREW ASSY 15 D7 Z16812 1 BRKT BYPASS PLASTIC BREW 16 2U 71061 1 FAUCET HOT WATER 17 2E 37465 1 TERM BLOC...

Page 24: ...W 2795TF INTERIOR COMPONENTS 20 655 2M Z17970 Owners Manual E Maxl Thermal Brewer SK2732 Rev 12 23 13 Model 2795TF E Max Thermal Brewer Tank Assy 7 13 14 17 18 19 20 21 22 16 15 6 1 2 3 4 5 8 11 12 9...

Page 25: ...FILL 90 DEGREE 8 2I 72390 1 GROMMET 375 ID TRANSLUCE 9 2K 70103 2 ELBOW OUTLET 10 2A 73384 3 TUBE SPRAY HEAD 2 3 8 LG 11 A6 73521 1 PROBE ASSY WATER LEVEL 12 2A 73532 1 SLEEVE WATER LEVEL PROBE 13 2I...

Page 26: ...OT 3 DUMP LINE 2 INLET LINE 1 HEATER LINE 3 WP1 2 WP2 1 WP3 1 2 3 4 HI LIMIT THERMOSTAT HI LIMIT THERMOSTAT TRIAC WARMER SWITCH 2121 ONLY WARMER ELEMENT 2121 ONLY HEATING ELEMENT LEFT 120V 1500W HEATI...

Page 27: ...27 655 2M Z17970 Owners Manual E Maxl Thermal Brewer NOTES...

Page 28: ...10 Sunnen Drive St Louis MO 63143 telephone 314 678 6336 fax 314 781 2714 www bloomfieldworldwide com...

Reviews: