The following parameters can be modified:
Login: is the Administrator’s login (10 characters maximum):
This login allows the user to make changes to any
area of the unit. The factory default Login is “Admin”. Login is case sensitive.
Current Password:
is the Administrator’s Current Password (10 characters maximum). The factory default password
is “pass”. The password is case sensitive and will not be displayed.
New Password:
used only if the user wants to change the current Administrator's password. Must enter a new
password (10 characters maximum). Password is case sensitive and will not be displayed.
Confirm New Password:
user must enter the same password as entered in above. If password entered in &
does not match, an error will be displayed.
Guest Login: is the Guest login (10 characters maximum):
This login allows the user to view the unit settings but
does not allow any changes. The factory default Guest Login is “Guest”. Login is case sensitive.
Current Guest Password:
is the current Guest Password (10 characters maximum). The factory default Guest
password is “pass”. The password is case sensitive and will not be displayed.
New Guest Password:
used only if the user wants to change the current Guest password. Must enter a new
password (10 characters maximum). Password is case sensitive and will not be displayed.
Confirm Guest Password:
user must enter the same password as entered in above. If password entered in &
does not match, an error will be displayed.
System Watchdog:
when Enabled, automatically reboots the unit, if the operating system stops working or the
status LED turns status green or off. When disabled, manual reboot is required in case of above events. Possible
options are enabled and disabled.
System Reboot:
allows the user to remotely reboot the unit.
SFP1 IP Address:
the control port factory default IP address is 172.16.70.1.
SFP1 Subnet Mask:
is the Subnet Mask assigned to the Control Port of the unit. It allows the user to determine
which subnet the Control Port IP address belongs to. The factory default Subnet Mask is 255.255.255.0.
SFP 1 Default Gateway:
is the gateway address assigned to the Control Port. It allows the user to access the unit
from another network via the web interface. The factory default Gateway is 172.16.70.254.
SFP 4 IP Address:
is the static IP address assigned to the GigE port. The default address is 192.168.253.1.
SFP 4 Subnet Mask:
is the Subnet Mask address assigned to the GigE port. Allows the user to determine which
subnet the GigE IP address belongs to. The factory default Subnet Mask is 255.255.255.0.
SFP 4 Default Gateway:
is the gateway address assigned to the GigE port. It allows the user to access the IP output
of the unit from another network. The factory default is 192.168.253.254.
Event Log Destination:
is the IP address of the remote server, to which Syslog sends the activities recorded by SDE-
6S-ASI for monitoring and troubleshooting purposes. The factory default value is 172.16.70.2.
Log Destination Port:
is the Event Log Destination port to which a duplicate of the error messages created by the
unit can be forwarded for monitoring and troubleshooting purposes. The factory default value, which cannot be
modified, is 514.
Time Server IP:
is the IP address for the Time Server from where the unit can obtain its clock reference (See Section
5.8 for details). The factory default value is 172.16.70.2.
Syslog Errors:
enable/disables the SDE-6S-ASI to forward error messages (in red font) to an SNMP syslog. The
factory default value is disabled.
Syslog Informational:
enable/disables the SDE-6S-ASI to forward information messages (in blue font) to an SNMP
syslog. The factory default value is disabled.
Syslog Feedback:
enable/disables the SDE-6S-ASI to forward feedback or confirmation messages (in green font) to
an SNMP syslog. The factory default value is disabled.
8
9
10
11
1
2
3
4
5
6
7
Remember to click on the SAVE button to apply the new values/configurations.