Section 3 – Installation & Power-up
3.1 Unpacking
You will find the following items in the box:
• SDE-6S-ASI-- Encoder (QTY=1)
• Power Cord with IEC C13 line socket and 3-pin Type B NEMA 5 plug (QTY=1)
• A hardware bag (item 741022200) containing the following:
Seven-foot cross-pinned (cross-over) RJ45 Ethernet cable (QTY=1)
SFP Transceiver (QTY-2)
4 Pin Plug (QTY=1)
12 Pin Plug (QTY=1)
10 Pin Plug (QTY=8)
Six-foot DVI to HDMI cable (QTY=1)
3.2 Installation
The SDE-6S-ASI encoder is designed to be installed in a standard 19-inch (483 mm) rack (EIA 310-D, IEC 60297, and DIN 41494
SC48D).
To install the encoder, secure the unit’s front panel to the rack by inserting four (4) machine screws, with cup washers,
through the four (4) mounting holes in the front panel.
3.3 Power-up
110/230 VAC Encoders (Stk# 6365) :
Connect the line cord to a 110/230 VAC, 60/50 Hz outlet. Please note that the IEC power connector on the rear panel of
the unit is equipped with an ON/OFF switch and a fuse (SLO-BLO, 3.0 Amp, 250V). The “POWER” LED on the front-panel
will light green.
-48 VDC Encoders (Stk# 6365 48) :
Connect the positive and negative leads from the batteries to the rear panel terminal strip.
For safe and reliable operation, the ground pin of the power cord plug must be grounded properly.