background image

3

Clearview

+

Quick Guide

Step 2: Connecting to a PC/Laptop

ETHERNET ACCESS:

Local or remote communication with the unit is only possible through a GUI-based menu via web browser (Chrome or Firefox 

is recommended)

. Before you can communicate with the unit, you must configure your computer's IP address to be in the 

same subnet as the units default IP address. To do so, follow these steps:

Connect one end of the Ethernet cable to the “

Control

” port on the unit front-panel interface. Connect the other end 

of the Ethernet cable to your computer.

The factory default IP address of the Control port is “

172.16.70.1

”. In order to communicate with the Control port, you 

must first change your computer's IP address.

1

2

The following steps explain how to do this for a computer with  

Windows 7

Windows 8.x

 or 

Windows 10

 operating software: 

(a) On your computer, navigate to the “Network and Sharing Center”.

     

 (Note: It can be found using the search box in the Start Menu or for Windows 8.x, the Start Screen)

(b) Once open, click on “Change Adapter Settings” on left hand side of the window.
(c) Right-click on the “Local Area Connection”, and then click on the “Properties”.
(d) A dialog box entitled “Local Area Connection Properties” will appear. In this box, double-click on the “Internet 

Protocol Version 4 (TCP/IPv4)”.
(e) A dialog box entitled “Internet Protocol Version 4 (TCP/IPv4) Properties” will appear. Select the “Use the following 

IP address” option and enter the following addresses:

IP address: 

172.16.70.2

Subnet mask: 

255.255.255.0

No need to enter a value for the Default Gateway.

Click OK to close the dialog box. Your computer is now ready to communicate with the unit.

IMPORTANT NOTE ON PORT CONFIGURATION

The “

Control

” port and “

IP Video”

  port  should  not  be  configured  to  be  within  the  same  IP  subnet.  

The “

Control

” port and “

IP Video

” port should also not be physically connected to the same network 

without proper network segmentation.

It is possible to access the unit's user interface via the “

IP Video

” port by using the IP address assigned 

to XC1.

Step 3: Login to the Controller

An Ethernet Cable should be connected between your PC and the “

Control

” port on the unit. Open a Web browser (Chrome 

or Firefox recommended) and type 

http://172.16.70.1

 in to your web browser to view and configure your 

Clearview

+

. Enter 

the username “

Admin

” and “

pass

” as the password and click [LOG IN]. 

Summary of Contents for Clearview+

Page 1: ...f their respective owners Blonder Tongue Labs Inc ISO 9001 2015 Certified P N 651251900A Rev 090920 Quick Guide HD Transcoder MPEG 2 H 264 AVC H 265 HEVC for up to 24 SPTS Programs Stock Model Name Description 6557 1 Clearview MPEG 2 H 264 AVC H 265 HEVC to MPEG 2 H 264 AVC H 265 HEVC HD Transcoder ...

Page 2: ...igital AC3 AAC MPEG1 Layer2 pass through only and MP3 1080i to 720p or 720p to 1080i resolution conversions yields improved compatibility bandwidth savings 24 front panel Status LEDs one 1 per each program stream Front panel Temperature LED Easy to use GUI for monitoring and control Before You Begin You will find the following items in the box Clearview Transcoder QTY 1 Power Cord with IEC C13 lin...

Page 3: ...ight click on the Local Area Connection and then click on the Properties d A dialog box entitled Local Area Connection Properties will appear In this box double click on the Internet Protocol Version 4 TCP IPv4 e A dialog box entitled Internet Protocol Version 4 TCP IPv4 Properties will appear Select the Use the following IP address option and enter the following addresses IP address 172 16 70 2 S...

Page 4: ...features a recent logged message box beneath the main status area which shows the 10 most recent entries within the Event Log To see a more in depth log of event messages click the Log tab located on the right side of the navigation menu at the top Step 4 Basic Configuration System Status Once you are logged into the unit you will be presented with the System Status page Status tab Status Page Ful...

Page 5: ...cated on the right side The visual representation of the transcode pipeline on the left side is interactive Clicking on a Transcode block displays the corresponding settings in the Video Audio Pipeline Settings table located on the right side The corresponding tab is also highlighted for persistent indication of the Transcode pipeline settings currently being shown Step 5 Transcoder Configuration ...

Page 6: ...also shown on the left side When hovering over a Transcode block the corresponding status table highlights Transcoders Status Page Visual and Informational Status Pipeline Status States Light Gray Red Question Mark The transcoder has not been detected yet Light Gray The transcoder is disabled Dark Gray Orange Arrow The transcoder is idle Green The transcoder is active Red The transcode has failed ...

Page 7: ...55 255 0 0 3 The Management PC is configured to be at 192 168 3 5 with a subnet mask of 255 255 0 0 Note The subnet mask of the Video Source Sink device must be configured to be on the same subnet mask as the Management PC Accessing devices from the Management PC To access the Video Source Sink device go to http 192 168 3 18 To access the Clearview unit go to http 192 168 6 60 Note Additional Clea...

Page 8: ...ent at 1 800 523 6049 Ext 4256 or visit our website www blondertongue com for further information Product and Documentation Updates Download the latest User Manual PDF by visiting our website Navigate to the product page by entering the full Model Name or Stock Number in the search field Upon reaching the product page the User Manual download link will be located beneath the product image Firmware...