background image

Operation

37

IQ Control

Programming the oven size

1. The top display reads 

APPL

. The bottom disĆ

play  reads  either 

FULL

  or 

HALF

.  Press  the

TOGGLE/CLEAR  KEY  (10)  until  the  bottom

display reads 

HALF

 for the CTBRĆAP.

2. Press the SCAN KEY (14) to enter the oven

size  and  continue  with  exiting  the  programĆ

ming mode.

Exiting the programming mode

1. The top display reads 

SYS

. Press the PROG

KEY (9). The control returns to the operating

standby mode.

Parameter

KFC Default

Hold mode

NO

Setback

NO

Temperature Units

_

F

Appliance Size

HALF

Programming the Offset

Call  Blodgett  service  for  offset  programming  inĆ

structions.

REPLACING THE RECIPE CARD

1. Remove the two screws from the top and botĆ

tom  of  the  control  panel cover.  Remove  the

cover.

NOTE: Inspect the control gasket. If damaged

call Blodgett service for replacement.

2. Pull back the control decal.
3. Remove the old recipe card.
4. Insert the new recipe card.
5. Replace the control decal.
6. Replace the control cover.
7. Reinstall the screws.

ERROR CODES AND ALARMS

NOTE: The error codes will appear in the top disĆ

play. All error codes are accompanied by

an audible alarm.

Hi

Oven  temperature  is  more  than

40

_

F above the highest setpoint.

Prob

Probe failure.

HEAT ERR

From a cool start (below 130

_

F), the

oven takes more than 6 minutes to

climb  from  150Ć300

_

F.  Press  the

TOGGLE/CLEAR KEY (10) to clear

the  prompt.  This  code  indicates  a

problem with the system. Contact a

service technician.

FAN ERR

Indicates a fan failure during a call

for heat. Press the TOGGLE/CLEAR

KEY (10) to clear the alarm. The FAN

ERR  display  remains  active.  Press

the TOGGLE/CLEAR KEY (10) again

to clear the message and return the

system to normal operation. If conĆ

dition persists turn off the oven and

contact a service technician.

FANC ERR

Indicates  a  contact  failure  has  ocĆ

curred  in  the  fan  control  circuit.

Press the TOGGLE/CLEAR KEY (10)

to  clear  the  alarm. The FANC ERR

display  remains  active.  Press  the

TOGGLE/CLEAR KEY (10) again to

clear  the  message  and  return  the

system to normal operation. If conĆ

dition persists turn off the oven and

contact a service technician.

DOOR OPEN

The  controller  senses  the  door  is

open. Close the door.  If the  door is

closed contact a service technician.

Summary of Contents for CTBR-AP

Page 1: ...om 44 Lakeside Avenue Burlington Vermont 05401 USA Telephone 802 658 6600 Fax 802 864 0183 PN 34532 Rev G 5 07 E 2007 G S Blodgett Corporation CTBR AP KFC ALL PURPOSE HALF SIZE ELECTRIC CONVECTION OVE...

Page 2: ...IN STRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT The information contained in this manual is important for the proper installation use and maintenance of this oven Adherence to t...

Page 3: ...ovens for every foodservice operation regardless of size application or budget In fact no one offers more models sizes and oven applications than Blodgett gas and electric full size half size counter...

Page 4: ...Your Service Agency s Address Model Serial Number Your oven was installed by Your oven s installation was checked by...

Page 5: ...on 13 Operational Test Procedure 14 Recipe Review 14 View Temperature Setting 14 Cool Down 14 Setback 15 Programming 15 Changing the Menu Strip 16 Recipe Programming 1724 17 System Programming 6647 22...

Page 6: ...y lost is recircu lated within the cooking chamber before being vented from the oven resulting in substantial re ductions in energy consumption and enhanced oven performance Amperes Electrical Connect...

Page 7: ...s tibles such as paper cardboard and flammable liquids and solvents To ensure proper operation ventilation must not be obstructed in any way Tripping of the blower motor thermal overload protective de...

Page 8: ...Smoke and Grease Laden Vapors from Commercial Cooking Equipment NFPA 96 Latest Edition General export installations Installation must conform with Local and National installation standards Local inst...

Page 9: ...he shelf holes with the bolt holes found near the bottom of each leg 6 Insert a carriage bolt from the outside of the leg through the leg and through the shelf cor ner bracket 7 Place a lock washer an...

Page 10: ...f the oven with the bolt holes in the stand 6 Insert a bolt and washer from the top down through each of the two holes 7 Place a nut and washer on each of the bolts and tighten securely 8 Replace the...

Page 11: ...igurations available for the CTBR AP D Two CTBR AP ovens D CTB biscuit oven stacked on top of a CTBR AP D CTBR AP stacked on top of a Mark V See pages 8 10 for stacking instructions for all configurat...

Page 12: ...in the top of the low er section near the left hand corners 6 Lay the upper section on its back Attach the self adhesive gasket tape to the front and side edges on the bottom of the unit See Figure 4...

Page 13: ...the unit See Figure 6 8 Set the CTBR AP upright on top of the Mark V 9 Remove the control compartment cover and access panel from the CTBR AP 10 Align the front and rear bolt holes of the CTBR AP wit...

Page 14: ...ation 10 Oven Assembly Attaching the Stacking Plate to the Mark V Stacking Plate Crown Trim Attaching the CTBR AP to the Stacking Plate See View A View A Stud Stud Top Cap Gasket Tape Stacking Plate F...

Page 15: ...eld with the vent guard Align the mounting holes in the vent shield with top holes in the vent guard 2 Insert the flue extension over the flue on the Mark V Attach using screws provided NOTE If the ov...

Page 16: ...N THIS MANUAL ARE FAMILIAR WITH THE FUNCTIONS OF THE OVEN AND OR HAVE HAD PREVIOUS EXPERIENCE WITH THE OP ERATION OF THE EQUIPMENT DESCRIBED AD HERENCE TO THE PROCEDURES RECOM MENDED HEREIN WILL ASSUR...

Page 17: ...s S Used to activate cook cycles and for certain programming functions 6 SCAN key S Used for recipe review during idle S Used to review time remaining during multiple cooks press hold 7 COOL DOWN key...

Page 18: ...ro grammed for each product key 1 Press the SCAN key 2 Select any product key previously pro grammed LED will be lit above the key 3 Press the DOWN arrow key to scroll through the list 4 Press SCAN to...

Page 19: ...e for the Vision Controller is en tered by pressing the P key for three 3 sec onds The following programming mode is avail able on the VVC 208 as follows Access Level Passcode Employees 1724 Managers...

Page 20: ...ews that secure the bezel of the VVC 208 in place Remove the bezel 3 Remove the existing menu strip s by lifting the tab and pulling the menu strip out from the bottom of the controller 4 Using the ta...

Page 21: ...er Pass Code 2 S Press the product key to be programmed That key s LED will remain lit S Scroll to the feature you want changed and press the P key NOTE Selecting ALL al lows you to review and or chan...

Page 22: ...Range is from 140 to 500F or the equiv alent of Degrees C S Press the P key to advance to the next stage or parameter STAGE 1 TEMP XXX F Set Stage 1 Temperature 6 S Press the LEFT or RIGHT ar row keys...

Page 23: ...advance to next stage or parameter STAGE 1 FAN ON Set Stage 1 Fan ON 9A NOTE THIS SECTION ONLY APPEARS IF PULSE IS SELECTED FOR FAN CYCLE S Type in desired fan OFF time S Press the P key to advance to...

Page 24: ...RM 1 DONE AUTOMATIC MANUAL Set Alarm 1 Done Mode selectable 13 S Press the LEFT or RIGHT ar row keys to select Alarm Tone S Press the P key to advance to next stage or parameter ALARM 1 TONE SHORT MED...

Page 25: ...18 S Press the LEFT or RIGHT ar row keys to select the hold fan speed S Press the P key to advance to the next step or parameter HOLD FAN SPEED HIGH LOW Set Hold Fan Speed 19 S Type in the proper cou...

Page 26: ...splayed S Press the P key again to en ter System Programming ENTER CODE Enter pass code 2 S Press the LEFT or RIGHT arrow keys to select from a pre pro grammed list of appliances NOTE Changing applian...

Page 27: ...uct keys to select the time in HH MM format for activating Setback mode NOTE 0 00 is default to dis able Setback S Press the P key to lock in your entry SETBACK TIME HH MM Program Setback Time 7 S Pre...

Page 28: ...old Done 11 S Press the LEFT or RIGHT ar row keys to select Hold Fan Speed S Press the P key to advance to the next stage or parameter HOLD FAN SPEED HIGH LOW Set Hold Fan Speed 12 S Type in the desir...

Page 29: ...the P key to lock in your entry SYSTEM PROGRAMMING Enter Pass Code 2 S Scroll to Prod Name Lib or Alarm Lib S Press the P key to advance PROD NAME LIB Or ALARM LIB 3 From this point you can either MOD...

Page 30: ...keys to move the cursor S Press HOLD to toggle be tween Upper and Lower case S TEMP TOGGLE CLEAR can be used to clear the existing product name S Press the P key to complete 4C S Press the LEFT or RI...

Page 31: ...S Press P to advance ENTER CODE Enter Pass Code 2 S Press the LEFT or RIGHT ar row keys to scroll through the SCK address to be used for this controller The range is from 1 to 31 or Auto Assign S Pre...

Page 32: ...to enter the cool down mode 9 PROG KEY press to enter the programming mode 10 TOGGLE CLEAR KEY press during pro gramming to toggle options or clear display 11 ACT TEMP KEY press to display the actual...

Page 33: ...ttom display flashes 00 00 4 Press the selected product key to silence the alarm Remove the product Multiple Batch Cooking Procedure This procedure is for single stage recipes with the same cook tempe...

Page 34: ...SCAN KEY 14 and the desired product key simultaneously The top display reads HdXX NOTE Hd indicates the head count function XX indicates product 1 to 16 The bottom display gives the total number of he...

Page 35: ...ook temperature Programming the Cook Temperature 1 The top display reads Ct 1 The bottom dis play gives the current cook temperature Use the product keys to enter the desired cook temperature 2 Press...

Page 36: ...to enter the desired time for the first alarm Press the ENTER KEY 13 to enter the PreAlarm time NOTE PreAlarm times are measured from the end of the total cook time For example if the total cook time...

Page 37: ...is recipe Once the number of stages has been estab lished the control will only allow en tries for these stages on all further pa rameters for this product 4 Press the ENTER KEY 13 again The display r...

Page 38: ...ired pulse off time from 10 to 60 seconds Press the SCAN KEY 14 The control advances to the next stage programmed for the pulse fan option NOTE Repeat Steps 4 5 to program cycle times for all pulse fa...

Page 39: ...ey 2 Press the SCAN KEY 14 3 The top display reads AUTO The bottom dis play reads either YES or no Press the TOGGLE CLEAR KEY 10 to toggle between YES and no Press the SCAN KEY 14 to enter the PreAlar...

Page 40: ...y reads FAn The bottom display gives the current fan mode To change the fan mode press the TOGGLE CLEAR KEY 10 The bottom display toggles between Hi and Lo Press the SCAN KEY 14 to enter the new fan m...

Page 41: ...ALARMS NOTE The error codes will appear in the top dis play All error codes are accompanied by an audible alarm Hi Oven temperature is more than 40_F above the highest setpoint Prob Probe failure HEAT...

Page 42: ...1 Use the L shaped brush to clean behind the probe 2 Use a damp towel to wipe the probe Cleaning Behind the Baffle Panel 1 Use the hand brush to clean around the heat ing element area behind the baff...

Page 43: ...of multiple FAST con trollers D use the SCKR Link Software for the purpose of permanently connecting the FAST controller to a terminal a computer server or another con troller This requirement stands...

Page 44: ...ER CHANTABILITY OR FITNESS WITH REGARD TO THE SCKR LINK SOFTWARE 9 No Liability for Consequential Damages IN NO EVENT SHALL FAST BE LIABLE FOR ANY LOST OR ANTICIPATED PROFITS OR ANY INCIDENTAL EXEMPLA...

Reviews: