Installation
8
Utility Connections
COLD WATER CONNECTION
Connect the appliance to quality water via a pres-
sure hose with 3/4” couplings. A shut off valve is
to be provided adjacent to the oven.
3/4” Coupling
1/2” appliance hose
with 3/4” hose fittings.
Appliance
Solenoid
Washer
Figure 2
Water must meet the following minimum require-
ments:
D
Total Dissolved Solids (TDS) content will not ex-
ceed 30 parts per million.
D
Water PH must be 7.0 or higher
WARNING!!
The use of poor quality water will invali-
date your warranty.
DRAIN CONNECTION
The Drain Vent assembly, included with the unit,
and a 2” (5 cm) copper pipe with standard drain
pitch, must be run to an open drain or connected
to a standpipe equipped with a vent.
NOTE: The waste water can also be directed to a
nearby floor drain. Flexible hose which al-
lows trapped water to accumulate in
sagged runs must be avoided.
WARNING!!
Failure to install the drain kit provided will
invalidate your warranty.
2” (5 cm) Drain
(Customer Supplied)
To Drain
Figure 3
A 24” (61 cm) long standpipe must be connected
to the DWV. This allows the escaping water vapor
to exit above the inlet louvers on the back panel.
Breather Vent
Plumber Installed
Connection
Tee, Hose and Clamps
Plumber Installed
Connection To Drain
Figure 4