BCX14G LOGIC BOARD ( J1 ) CONNECTOR VOLTAGE TEST POINTS
FIGURE 2
24
L
OGIC BOARD VOLTAGE TEST POINTS AT (
J1 CONNECTOR)
From (J1-1) BK 24Dcv_Rtn_L to (J1-4) RD +24Dcv_H
(
Always live with circuit breaker On
)
J3
J4
J1-4
RD
J1-1
BK
J1
J
24DCV
- +
Trouble shooting test points!
Your volt meter leads should insert
right into the LH side of the
J1
connector through a hole provided
from the factory for test points.
This connector will provide the
best test points while testing for a
24Dcv_Rtn_L, with your meter
Red lead into (J1-4)-RD +24Dcv
and your Black lead testing for the
24Dcv_Rtn_L.
Or your meter Black lead into the
(J1-1)-BK 24Dcv_Rtn_L and your
Red lead testing for a +24Dcv_H.