Page 11
BCX, BX NEW MANUAL CONTROL
Factory Level Programming Code: 3228
(The oven needs to be in the “OFF” position)
(P-20)
Upper Ready Band
25F
(P-21)
Lower Ready Band
10F
(P-22)
Cavity Probe Offset
0F
(P-23)
Core Probe Offset
-2F
(P-24)
Spritzer Solenoid Duty Cycle
33
(P-25)
User Response Timeout
5
(P-26)
Sleep Mode Timeout
1
(P-27)
Counter Start Delay
2
(P-28)
Quench Probe
Yes
(P-29)
SCK Address
30
(P-31)
ACT Oven Temp Display
No
(P-32)
Remote Beeper
Yes
Press Dial to Exit
Scroll to END
Press Dial to Exit
End Of Factory Programming
(P-33)
Setback time
0:00
(P-34)
Setback Temp
300F
(P-35)
Setback Temp Delta
10F
(P-36)
Download Factory Settings From SD
(P-37)
Upload factory Settings to SD
(P-38) Cavity high limit
650F
(P-39) Boiler high limit
250F
(P-40) Cool fan high limit
167F
(P-41) Cook cool fan set temp
95F
(P-42) Idle cook fan set temp
105F
(P-43) 24Vdc input detection
No
(P-44) Quench probe set temp
150F
(P-45) Boiler preheat temp
185F
(P-46) Boil super steam temp
212F
(P-47) Boiler probe offset
0F
(P-48) Core probe type
1K
(P-49) No heat error
15:00
(P-50) Fan error detect time
00:15