Page 8
BCX, BX – NEW MANUAL CONTROL
Service Level Programming
Code: 7378
(The oven needs to be in the “OFF” position)
Press the Timer Dial Till
“0000” Is Displayed
Turn the Dial:
Scroll the flashing # to (7)000
Press the Dial to Enter
Scroll the flashing # to 7(3)00
Press the Dial to Enter
Scroll the flashing # to 73(7)0
Press the Dial to Enter
Scroll the flashing # to 737(8)
Press the Dial to Enter
Scroll to (DIAG) Diagnostics
Press the Dial to Enter
“D-01” Is Displayed
(Cavity Heat Relay)
Press the Dial to Enter
Turn Dial CW to “ON”
Turn Dial CCW to “OFF”
Press the Dial to EXIT
(CONTINUE)
(FOLLOW STEPS ABOVE)
Scroll the Dial to D-02
Boiler Heat Relay
D-03
Water High Level Switch Status
D-04
Water Low Level Switch Status
D-05
Drain Relay
D-06
Fill Relay
D-07
Steam Relay
D-08
Quench Relay
D-09
Motor-Reversals Relay Gently
D-10
Motor Gently
D-11
Motor Low
D-12
Motor High
D-13
Motor Turbo
D-14
Door Status
D-15
Lights Relay
D-16
Delime Pump Relay
D-17
Software Flash Number
D-18
Software Number
D-19
Software Download Number