Page 10
BCX, BX – NEW MANUAL CONTROL
Factory Level Programming
Code: 3228
(The oven needs to be in the “OFF” position)
Press the Timer Dial Till
“0000” Is Displayed
Turn the Dial:
Scroll the flashing # to (3)000
Press the Dial to Enter
Scroll the flashing # to 3(2)00
Press the Dial to Enter
Scroll the flashing # to 32(2)0
Press the Dial to Enter
Scroll the flashing # to 322(8)
Press the Dial to Enter
“P-01” Is Displayed
Press the Dial to View
Turn Dial to: (F)
Press the Dial to Retune
Turn Dial to: P-02
(CONTINUE)
(FOLLOW STEPS ABOVE)
P-##
“ Set To “
(P-02)
Cool Down Temp
100F
(P-03)
Ready Beep
ON
(P-04)
Fan Reverse Time
6:00
(P-05)
Cook Done Beeper
Yes
(P-06)
Delime Interval
30 Hours
(P-07)
Flush Interval
24 Hours
(P-08)
Appliance Type
Gas
(P-09)
Machine Type
BCX / BX
(P-10)
Max Steam On Demand
20
(P-11)
Min Hot Air Set Point
140F
(P-12)
Max Hot Air Set Point
500
(P-13)
Min Steam Set Point
85F
(P-14)
Max Steam Set Point
225F
(P-15)
Max Core Probe Pull Temp
200F
(P-16)
Upper Hot Air Hysteresis
1F
(P-17)
Lower Hot Air Hysteresis
1F
(P-18)
Upper Steam Hysteresis
1F
(P-19)
Lower Steam Hysteresis
1F