Pentland Wholesale Ltd. Page
6
of
13
4.3
Electrical Connection
Check that the supply conforms with the requirements listed on the factory label
and that it is provided with a circuit breaker with sufficient earth connection. Should
there be none present, ensure one is supplied and installed by a suitably qualified
engineer by means of an omnipolar switch as indicated in the safety regulations
with a minimum clearance of the contacts of
3mm
.
Where the cabinet has to be stored at distance from the power supply, ensure that
the ensuing connection conforms to all local safety regulations. Cabinets supplied
with integral condensing units are supplied with an appropriate plug fitted with
Neutral and Earth.
The supply cable must be well stretched to avoid coiling and superimposition and it
must not be exposed to the possibility of damage by third parties. It should be kept
clear of liquids, water or heat sources and in the event of damage, must be
replaced by a suitably qualified person.
4.4
Connection to Drains
The evaporation of the defrost water is automatic in all models with an integral
condensing unit.