Operating instructions
Mounting
5
104485 • 03/03
3.4
Checking the rotating direction
Caution
Fire hazard and damage to compressor
in case of wrong polarisation of the
motor (5 revolutions maximum in the
wrong direction of rotation!)
•
Carry out the check of the rotating di-
rection as described below:
!
Open side cladding of the compressor.
!
Please refer to chapter 4.2 titled “Switch-
ing the unit on”.
!
Press the power switch, and immediately
after this the circuit-breaking key (see fig.
2: Operating elements). The correct rotat-
ing direction of the fan has been marked
by an arrow on the fan cover.
!
Change the poles of the electric connec-
tion of the motor in case of a wrong rotat-
ing direction.