Via Montefeltro, 6 – 20156 Milano (MI) – Italy
- 24 -
Tel. +39 (02) 3088583 – Fax +39 (02) 33406697
www.blinkmarine.com
–
PK-1400_CANOpen_UM_REV1.3
30.
Object 100Ah: Manufacturer Firmware Revision
Identifier
600h + current CAN ID
Default 615h
Byte 0
40h
Read Device Register
Byte 1
0Ah
CAN Object 100Ah
Byte 2
10h
Byte 3, 7
00h
Not used
Example:
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
40 0A 10 00 00 00 00 00
Keypad reply
595
Std
43 0A 10 00 30 2E 32 56 V2.0
Manufacturer Firmware Revision: V2.0
31.
Object 100Bh: Model ID
Identifier
600h + current CAN ID
Default 615h
Byte 0
40h
Read Device Register
Byte 1
0Bh
CAN Object 100Bh
Byte 2
10h
Byte 3, 7
00h
Not used
1
°
additional byte
Identifier
600h + current CAN ID
Default 615h
Byte 0
60h
Read Device Register second byte
Byte 1, 7
00h
Not used
Example:
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
40 0B 10 00 00 00 00 00
Keypad reply
595
Std
41 0B 10 00 07 00 00 00
To Keypad
615
Std
60 00 00 00 00 00 00 00
Keypad reply
595
Std
01 50 4B 31 34 30 30 00
PK1400
Model ID: PK1400