2 BBL Hybrid™ 2 Vessel Brewhouse V2

© Blichmann Engineering, LLC 2019 

For replacement parts, visit: blichmannengineering.com/genuine-replacement-parts

6

RTD Wiring Inside Control Panel

Boil Kettle
White to BKTS-1
Red to BKTS-2
Blue to BKTS-3

Mash Tun
White to MTS-1
Red to MTS-2
Blue to MTS-3

RTD Terminals

Low Level Float Switch

Fig. 10

Heating Element Terminals

Heating Element Grounds

BK

 Elements

Heating Elements:  

The brewhouse is supplied with four 6,000 W ultra-low watt density heating elements. 

Each heating element will draw 25A at 240V (single phase) or 17A at 208V (three phase).  Each single phase 
element is pre-wired for 240V operation and has a pigtail with an L6-30P twist lock connector for easy removal 
for cleaning.  Each three phase element is pre-wired for 208V operation and has a pigtail with an L14-30P twist 
lock connector for easy removal for cleaning. We recommend SJOOW type cable 10 ga minimum.  Again, your 
local codes will dictate the cable type and gauge.

IMPORTANT: 

Always consult your local codes to determine what type of cable is acceptable, what gauge is 

required, and maximum lengths of flexible cable allowed.

Your system is supplied with PT100 RTD temperature probes with 30 feet of cable. Insert the Temperature Probe into the cord grip and thermowell 

until the probe bottoms out. It is important to ensure it is inserted all the way, otherwise this can cause your temperature readings to be inaccurate. 

Tighten the cord grip until the probe cable is locked into place. 

Connect the white, red, and blue wires to the control panel listed below.

Summary of Contents for 2 BBL Hybrid Brewhouse

Page 1: ...ORMATION PLEASEREADANDTHOROUGHLYUNDERSTANDTHISMANUALPRIORTOUSE FORIMPORTANTSAFETYINFORMATION What sIntheBox Item Number Description Quantity BEPS MLT 2BBL 2BBLMashTun 1 BE 001346 02 2BBLFalseBottomAssembly 1 BEPS BK HLT 2BBL 2BBLBoilKettle 1 BEPS SanitaryHeater 2 2BBLSanitaryHeaterAssembly 2 LowLevelFloatSwitch 1 BEPS SanitaryHose 1in 10 10foot 1InchIDHose 1 BEPS SanitaryHose 1in 5 5foot 1InchIDHo...

Page 2: ...learance between kettles and also on the sides and rear to allow personnel access for cleaning and service of the ancillary equipment Although in practicaluse thekettlescaneasilybeslidoutforanyserviceneeds Installvalvesandfittingsasshownintheimagesbelow Notethata6 spoolisaddedtothemashtundraintoallowthevalvetoswingunderthestandsothata spentgraintotecanbeplacedunderthemanway Itisnotnecessarytoaddth...

Page 3: ...tallthestand pipeinthedrainfittinginsidethekettle asshown Toinstallandremovethe standpipe simplyusearackingcaneto loweritintothedrainholeandreverse forremoval Thiswillkeepthebulkofthe settledhopsandbreakmaterialinthe bottomofkettleandoutofthechiller Useofthestandpipe while recommended isoptional Ventilationneedsforanelectricbrewhousearefairlyminimalasonlytheboilkettleneedstobeventilated Werecommen...

Page 4: ...ngacertifiedelectricianforthiswork Thispanel isdesignedfor240VACsinglephasepoweronly Contactusfor3phasesystemoptions The back of the panel has 4 holes for affixing the panel to the wall of the brewhouse or onto a suitable stand Mounting hardware or stand is not included Theimagebelowindicatesthelocationsofthemaincomponents KettleTemperature Controllers PID s Heaters ON Indicator Lamps Heater Contr...

Page 5: ...rthemainpower cablesareconnectedtothepanel Consultyourlocalcodestodetermineifyouneedamaindisconnectaswell Inanycase wehighlyrecommendasuitable disconnectswitchbeinstalledpriortothepanelforsafeservicingofthepanel Yourcontractorwillneedtopunchaholeinyourpanelforthemainpowercable conduitinyourdesiredlocation Powerdemandforthebrewhouseis52Aat240V singlephase Selectamainbreakersettingfor20 abovetheappr...

Page 6: ...ockconnectorforeasyremoval forcleaning Eachthreephaseelementispre wiredfor208VoperationandhasapigtailwithanL14 30Ptwist lockconnectorforeasyremovalforcleaning WerecommendSJOOWtypecable10gaminimum Again your localcodeswilldictatethecabletypeandgauge IMPORTANT Alwaysconsultyourlocalcodestodeterminewhattypeofcableisacceptable whatgaugeis required andmaximumlengthsofflexiblecableallowed Your system is...

Page 7: ...tinuitytesterontheleadstoensurethattheswitchisopenwheninthedown empty position andisclosed hascontinuity intheup full position CAUTION The low water level switches are a backup to an unintended energizing of the heaters They are NOT intended to be normal shutoff switches and solely relied upon to keep the heaters from unintentionally energizing Dry fired heating elements are not covered under warr...

Page 8: ... cut power from the inside of the panel All internal components will be live To service the panel disconnectmainpowertothepanelbeforeopeningthepanel SanitizethechillerbyeitherpumpingStarSanorsimilarcopperfriendlysanitizerthroughthechiller Alternatelythechillermaybesubmerged fittingsup intoa pailofsanitizer Drainthechilleraftertherecommendedtimewiththefittingsfacingdown Connectthechillerpertheinstr...

Page 9: ...ughBlichmannEngineering Removethe falsebottomsectionsandspraythemoffwithhotwaterandallowtodry Sprayexcessgrainfromthesidewallsandbottomofthekettleswithahose BK MT Duetotheeasyaccessthroughthetopoftherelativelysmalltanks andsmallsizeofthechillerandpumps itisusuallyfastesttoscourthekettleswith ascrubbrushmountedonapoleandspraythemoutwithahose OptionalcleaningtoolsareavailablethroughBlichmannEngineer...

Page 10: ..._______ B Limitations ofWarranty 1 Any implied warranty that is found to arise by way of state or federal law including any implied warranty of merchantability or any implied warranty of fitness is limited in duration to the terms of this limited warranty and is limited in scope of coverage to this warranty Blichmann Engineering disclaims any express or implied warranty including any implied warra...

Reviews: