G4 Multi Channel Weighing Instrument
1-11
DeviceNet
Module type
DeviceNet fieldbus adaptor
Connector
5 pin male connector.
Baudrate
125, 250, 500 kbps or Auto. Set by parameter.
Address
0 – 63, set by parameter
Fieldbus data
16 bytes from fieldbus to instrument.
32 – 244 bytes from instrument to fieldbus (may be limited
by the master).
See chapter ‘Communication’ section
‘Fieldbus communication interface’ for details on fieldbus
data mapping.
Mounting
The fieldbus adaptor is mounted through the front of
the CPU module with LED’s and connector accessible
through the CPU front panel.
Remove the plastic cover from the fieldbus slot in the CPU
module front panel. Insert the adaptor very carefully and
make absolutely sure that the adaptor slides correctly into
the guides in the connector on the CPU PCB. Tighten
the two fastening screws at the adaptor front and check
that the two securing hooks locks into the CPU PCB.
Settings
All fieldbus settings are done with setup parameters in
the instrument. No settings are done on the module itself.
Bus Supply Voltage
According to the DeviceNet (Node) Specification:
nominal 24 VDC, range 11 – 25 VDC.
Summary of Contents for G4-DT
Page 1: ...G4 Multi Channel Weighing Instrument Program version 1 12 0 0 Technical Manual PM DT HE types ...
Page 2: ......
Page 18: ...Technical Manual 1 14 ...
Page 36: ...Technical Manual 2 18 ...
Page 41: ...G4 Multi Channel Weighing Instrument 3 5 ...
Page 154: ...Technical Manual 6 48 ...
Page 180: ......
Page 190: ...Technical Manual 9 10 ...
Page 191: ...G4 Multi Channel Weighing Instrument Appendix 1 ...
Page 192: ...Technical Manual ...
Page 193: ......