Technical Manual
5-14
WF IN / WF IN2 module filter bandwidth
Update
rate
- 3 dB frequency
- 90 dB frequency
Filtered
Unfiltered
Filtered
Unfiltered
300 Hz
14 Hz
22 Hz
75 Hz
150 Hz
150 Hz
7.6 Hz
14 Hz
37 Hz
75 Hz
75 Hz
3.9 Hz
7.6 Hz
19 Hz
37 Hz
37 Hz
2.0 Hz
3.9 Hz
9 Hz
19 Hz
19 Hz
1.0 Hz
2.0 Hz
4.5 Hz
9 Hz
9.3 Hz
0.5 Hz
1.0 Hz
2.3 Hz
4.6 Hz
4.6 Hz
0.25 Hz
0.5 Hz
1.2 Hz
2.3 Hz
2.3 Hz
0.12 Hz
0.25 Hz
0.6 Hz
1.2 Hz
HS WF2 module filter bandwidth
Update
rate
- 3 dB frequency
- 90 dB frequency
Filtered
Unfiltered
Filtered
Unfiltered
800 Hz
34 Hz
48 Hz
200 Hz
400 Hz
400 Hz
19 Hz
34 Hz
100 Hz
200 Hz
200 Hz
10 Hz
19 Hz
50 Hz
100 Hz
100 Hz
5.2 Hz
10 Hz
25 Hz
50 Hz
50 Hz
2.6 Hz
5.2 Hz
12 Hz
25 Hz
25 Hz
1.3 Hz
2.6 Hz
6 Hz
12 Hz
12.5 Hz
0.75 Hz
1.3 Hz
3 Hz
6 Hz
WF IN / WF IN2 Filter rise time
HS WF2 Filter rise time
Update
rate
Rise time
Update
rate
Rise time
Filtered
Unfiltered
Filtered
Unfiltered
300 Hz
0.075 s
0.04 s
800 Hz
0.028 s
0.015 s
150 Hz
0.15 s
0.08 s
400 Hz
0.055 s
0.030 s
75 Hz
0.30 s
0.16 s
200 Hz
0.11 s
0.060 s
37 Hz
0.60 s
0.32 s
100 Hz
0.22 s
0.12 s
19 Hz
1.2 s
0.64 s
50 Hz
0.44 s
0.24 s
9.3 Hz
2.4 s
1.3 s
25 Hz
0.88 s
0.48 s
4.6 Hz
4.7 s
2.6 s
12.5 Hz
1.8 s
0.96 s
2.3 Hz
9.4 s
5.1 s
Rise time is defined as the time from an ideal step input to output reaches 99 % of the
input step. Note that in reality no input changes will be an ideal step. Input signals are
affected by mechanical time constants and how the weight is applied to the scale.
Summary of Contents for G4-DT
Page 1: ...G4 Multi Channel Weighing Instrument Program version 1 12 0 0 Technical Manual PM DT HE types ...
Page 2: ......
Page 18: ...Technical Manual 1 14 ...
Page 36: ...Technical Manual 2 18 ...
Page 41: ...G4 Multi Channel Weighing Instrument 3 5 ...
Page 154: ...Technical Manual 6 48 ...
Page 180: ......
Page 190: ...Technical Manual 9 10 ...
Page 191: ...G4 Multi Channel Weighing Instrument Appendix 1 ...
Page 192: ...Technical Manual ...
Page 193: ......