79
E
N
G
L
IS
H
Configuration
I/O assignment menu
(continued)
(1) Assigning this function displays the corresponding settings in the SEt- menu so that they can be adjusted.
Code
Assignment
Factory
setting
-r2
Relay R2
no : not assigned
FtA : frequency threshold reached. The contact is closed if the motor frequency is
greater than or equal to the threshold set by Ftd (1).
CtA : current threshold reached. The contact is closed if the motor current is greater than
or equal to the threshold set by Ctd (1).
SrA : speed reference reached. The contact is closed if the motor frequency is greater than
or equal to the speed reference.
tSA : thermal threshold reached. The contact is closed if the motor thermal state is greater
than or equal to the threshold set by ttd (1).
SrA
-Add
Address of the speed controller when it is controlled via the serial link.
Adjustable from 1 to 31.
1
-bdr
Serial link transmission speed :
9.6 = 9600 bits / s or 19.2 = 19200 bits / s
Modification of this parameter is only taken into account after the speed controller has been
powered down then powered up.
19.2
I-0-